36
IP2159EN - 2017-06-12
17. Extension unit DAB905ESE (optional)
There is a command extension card for managing the electric lock / electric strike, function selector, batteries, key selector
switch and night-time closure.
17.1 Commands
Contact
Function - Accessory
Description
3
4
GND-OIMP
NO
OUTER SIDE OPENING
Contact for connection of external detection radar.
The closure of the contact activates an opening operation.
NB: this command is only active with the COM400MKB-MHB function selector switch.
3
5
GND-O/C
NO
STEP-BY-STEP
The closure of the contact activates an opening operation. The door stays open until a new
command is given.
If the door does not receive any command, it closes automatically after 15 minutes of inactivity.
Automatic closing cannot be adjusted using the HOT trimmer; it is factory-set.
The automatic closing time can be modified from 15 min to endless (∞), by altering the pre-
configured parameters as explained in chapter 14.
The opening/closing command only works in TWO-WAY mode.
Modify the operating mode to CLOSED door or ONE-WAY opening, altering the pre-config-
ured parameters as explained in chapter 14.
3
6
GND-KEY
NO
KEY OPENING
The closure of the contact activates an opening operation.
This command is always active, even when the COM400MHB/MKB function selector switch
or ON-OFF-HOLD OPEN switch is installed.
The automatic closure time is set to 5 s when the door is open regardless of HOT trimmer
adjustment.
Can be used for opening from night/CLOSED mode.
DAB905ESA
(optional)
DAB905ESE
(optional)
Torx T10
Long pin used for 2 Extension Unit
Short pin used for 1 Extension Unit only
5 mm nut driver
6
1 2 3 4 5
6 7 8
1 2 3 4 5
1 2
3 4 5 6 7 8 9 10 11 12 13
Fix the label to the terminal board, taking care to apply it in the correct
direction (see the figure above).
-
–
+
1
2
3
4
5
ON
+24 V DC
KILL
KEY
O/C
OIMP
GND
BATTERIE
1
2
3
45678
9
1
0
1
1
1
2
1
3
OPEN
EXIT
OFF
UNL
KRST
Serratura elettrica /
Incontro elettrico
12 V max 1,2 A
24 V max 600 mA
Apertura lato esterno
Passo passo
Apertura a chiave
Chiusura di emergenza
Reset chiusura di emergenza
Porta sbloccata
Temporizzatore porta chiusa
J
i
(optional)
Torx T10
5 mm nut driver
(optional)
Long pin used f
or 2 Ext
ension Unit
Short pin used f
or 1 Ext
ension Unit onl
y
BATTERIES
Closed door timer
Emergency closure reset
Key opening
Door released
Emergency closure
Step-by-step
Outer side opening
Electric lock / Electric strike