13
IP2159EN - 2017-06-12
Apertura a sinistra
• Prepare the set-up for fixing the automation to the wall, respecting the measurements shown in the figures above (with reference
to the hinge axis).
• Drill a hole in the door wing, in line with the fixing for the articulated arm.
• If necessary, use the DAB805SE2/SE5/SE7 extensions to increase the X measurement between the automation and the arm fixing points.
8. Automation with articulated arm DAB805PSA
8.1 Automation preparation and fastening
Before fixing the base plate [1], make holes for the cables to pass through.
i
11
=
=
Ø 16
Use the articulated arm for doors that open outwards (as seen from the automation side).
300
max
~400
107
X
OPENING
Left-hand opening
X+16
75
34
31
26
4
248
35
633
Shaft extension
X
/
30
DAB805SE2
50
DAB805SE5
80
DAB805SE7
100