Command Port Interface (SBUQHS/QHB)
80-14001000-03
4–9
D) CALL BACK
5
The incoming call’s
originating number is
checked against the CLID
store, the call is then
cleared, then the originator is
called back also using the
sub-address (if one is
entered) in the CLID store.
4.4.3.3 Leased Circuit Failures menu
Determines which criteria are used for determining DLC failure.
A) DATA LOSS
A) ENABLED
Monitors DLC Received data for
activity.
B) DISABLED (F)
Not monitored.
C) DATA LOSS
TIMER
Time over which loss of data
needs to occur to sense DLC
loss.
B) CLOCK LOSS
A) ENABLED
Monitors DLC clock for activity.
B) DISABLED (F)
Not monitored.
C) CLOCK LOSS
TIMER
Time over which there must be a
good clock for restoral purposes.
C) I/DSR LOSS
A) ENABLED
Monitors DLC I (X.21) or DSR
(V.24/V.35) for activity.
B) DISABLED (F)
Not monitored.
5
With Call Back enabled, the Delay After Attempt in the Cyclic Dial menu
must be set to at least 6 seconds at the calling unit, to allow for the call back
to occur.