Envoy-S Installation and Operation
2016 Enphase Energy Inc.
141-00031 Rev 01
47
Message Shown on
Events and Inventory
Screens
Description
Shutdown
Description:
The Envoy has been powered down (unplugged from AC power).
Recommended Action:
Restore AC power to the Envoy.
Startup
Description:
The Envoy has been powered back up (plugged back in to AC
power).
Recommended Action:
No action is required.
Tpm Profile Inverter
Incompatible
Recommended Action:
The microinverters may need to have a software upgrade
in order to be compatible with the selected grid profile. (The selected grid profile
defines operating parameters that are compatible with your grid service.) If a
microinverter software upgrade does not start automatically a few minutes after the
after Envoy has discovered all microinverters, contact Enphase Energy customer
support. Note that the Envoy requires a minimum of 3 bars to communicate
effectively with the microinverters for the software upgrade.
Description:
This message displays when the selected grid profile is incompatible
with microinverter software or hardware. This condition can affect your system’s
ability to produce power.
If the condition persists
: Contact
Enphase Energy customer support
(
enphase.com/global/support-request
)
.
Transient Grid Profile
Recommended Action:
No action is required. This condition will clear once the
grid profile test is complete.
Description:
This system is currently in test mode.