ENIGMA XM88422 Digital Receiver
Version 1.50
7
2. Quick Start
Receiver Setup and Operation
Unpacking
Carefully unpack the receiver and inspect the device
for shipping damage. If there is any apparent
damage, do not try to turn on the equipment, and
notify the carrier immediately. The package contents
are the following:
XM88422 Digital Receiver
(1 CPM, 1 LCM - 2 lines, 1 PWR)
AT Modem Cable
Instruction Manual
Introduction to Operation
Please, refer to the following chapters of this manual
to help you through the installation and operation of
the ENIGMA XM88422 digital receiver.
Chapter 3. Installation
Chapter 4. CPM Module
Chapter 5. Line Card Module
Chapter 6. Power Module
Bench Testing
It is highly recommended the receiver be tested
before commencing the actual installation, becoming
familiar with the connection and setup of the device,
and the receiver programming to make the final
installation more straightforward.
The following items are required for testing:
16.5V AC transformer
12V 6Ah battery with cables
2 telephone lines
a digital communicator, dialer or a control panel
capable for communication
Connect the transformer to the AC input terminal on
the backplane of the Power module. Connect the
battery cables to the BAT terminals with correct
polarity, but do not connect the battery to the cables
yet. (Note, that for connecting the transformer and
battery, you may have to disconnect the intercom
cable temporarily, and plug it back again after the AC
and battery connections have been made.)
Power Up
Powering up the unit starts with applying AC power to
the unit. After that, connect the battery to the battery
cables. The CPM unit carries out a comprehensive
memory test on power-up, which can take some time.
A counter in the upper-left corner of the CPM display
will count down during the memory test. If the CPM
finds any unreliable memory during the memory test,
it will stop, and display the faulty memory address on
the screen.
After the memory test had been finished, the CPM
resets the line cards. (The line cards may also reset
on power-up, and during the memory test they
display CPM error
– it is normal, wait until the CPM
resets the line cards after memory test). The line
cards will beep, and their LCD display will show line
trouble condition, if no phone lines are connected to
the appropriate line inputs on the line card backplane.
The CPM unit displays the list of trouble and restores
condition occurred since powering up the receiver. If
no computer with proper automation software is
connected the COM1 port of the receiver, the CPM
will beep after encountering the COM1 error condition
waiting for manual acknowledge. Pushing the OK
button on the CPM unit can silence the buzzer.
Operation with the default programming
Without any changes to the factory default
programming, the receiver operates normally with the
following specifications:
Default Program Access Password is 1234 (right-
left-down-up)
Line cards answer to incoming calls on the first
ring
Caller identification is disabled
The handshake sequence is 2300,1400,dual tone
and FSK answer tone
Handles all formats except for 3/2, 3/1+Chk and
Surgard DTMF 4/3+Chk. These formats can be
enabled with programming.
Reception of Extended formats is disabled
Two Way Audio (listen in) is disabled
The printer operates in backup mode
– prints
only events cannot be reported on COM1
If no computer connected, the events can be
acknowledged, and the buzzer silenced by
pressing the OK button on the CPM. The manual
acknowledgement will be registered with time
and date
COM1, Printer and Line Card operation
supervision is enabled.
Heartbeat
supervisory
protocol
enabled
heartbeat in every 30 seconds.
Содержание XM88422