ENIGMA XM88422 Digital Receiver
Version 1.50
17
Enter/Ack key to save the set values. A “Program
Change” event will be recorded. Pressing the Clr
button will exit the dialog box without making any
changes.
Receiver Number
The receiver number identifies the receiver for the
computer. This is important when multiple receivers
are connected to a computer. The value can be set
between 0 and 256. The default value is 01.
Heartbeat
Defines the interval of the heart-beat signals sent by
the receiver to the computer to verify the serial
connection. The interval can be set between 01 and
256 seconds. Programming 0 will disable the heart-
beat signals if the automation software is not
compatible with heart-beat protocol. The default
value is 30 seconds.
Clock Signal
The insertion of the Clock Signal Protocol can be
turned on and off here. The Clock Signal Protocol is
used to transmit time and date information together
with the event to the computer. The default setting is
off. The Clock Signal Protocol can also be
programmed to transmit the year or the second of the
event (S or Y). The default is to transmit the second
of the event.
Printer Mode
The operating mode of the printer can be selected.
The three options are:
NORMAL
All the events will be printed,
regardless of the status of COM1
BACKUP
only the events failed to report on
COM1 will be printed.
OFF
nothing will be printed.
The default setting is OFF.
External ACK
The operation of the external Acknowledge input of
the receiver can be enabled and disabled here. When
enabled, the events can be manually acknowledged
by a normally open pushbutton connected to the
external Acknowledge input of the receiver. The
default value is disabled.
Tamper Check
When enabled, a short between the receivers tamper
inp
uts will generate a “Receiver Tamper” status
event. This can be used to record receiver tampering,
when the receiver is installed in a closed cabinet with
access doors. The default setting is disabled.
Buzzer Mute
This option can silence the buzzer for debugging or
servicing purposes. Enabling this option is not
recommended for central monitoring stations,
because the receiver will not beep when an event
comes in and the serial connection is broken. The
default setting is disabled.
HotSwap Mode
This option is active when the receiver is used as a
hot backup for another ENIGMA. The default setting
is disabled.
LCD Contrast
The contrast of the LCD display can be set here. It
can be set from 0 to 15 (0Fh). The lower values
mean lighter display, larger values mean darker
display. The default setting is 8.
Line Card Setup
When Line Card setup is selected, a small dialog box
will appear where the number of the Line Card to be
programmed can be entered. Line Card numbers
between 01 and 31 can be entered, but the Line Card
number is valid only if the given Line Card is present
in the system.
If a valid Line Card number is entered, a dialog box
will appear with the parameters of the given Line
Card. If the addressed module is a Line Card, the
following will be displayed:
Nr.of Rings : 001 LCD Ctr: 8
Line Test : ON (020-240)
HSK Timing : 020-009-040-009
HSK Sequence: 1-2-3-4-0-0-0-0
2-way Audio : OFF (00-00/t000)
Format Opt. : 0-0 Ext: DISABLE
Caller ID : OFF Holdup: 000
Limit Calls : 000 Audio: OFF
Keep Display: OFF Debug: OFF
The currently selected field is flashing. Skip between
fields with the Left and Right buttons. The field
contents can be increased with the Up button and
decreased with the Down button. Pressing a button
continuously will repeat the action until the button is
released. After the fields are set correctly, press the
Enter/Ack key to save the set values. A “Program
Change” event will be recorded. Pressing the Clr
button will exit the dialog box without making any
changes.
The parameters are detailed in the Chapter 5. Line
Card Module.
Содержание XM88422