background image

ENFORCER 

Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

 

6

 

SECO-LARM U.S.A., Inc. 

Operating voltage  

12~24 VAC/VDC 

Current draw  

(at 12VDC) 

Standby 

55mA 

Keypress 

90mA 

Output 1 active 

105mA 

Output 1 & 2 active 

130mA 

Output 1, 2, & 3 active 

150mA 

Total max. current draw 

220mA 

Outputs 

#1 – Form C 

5A@24VDC 

#2 – Form C 

1A@24VDC 

#3 – Form C 

1A@24VDC 

K or A 

100mA@24VDC 

Duress 

100mA@24VDC 

Interlock 

100mA@24VDC 

Tamper 

50mA@24VDC 

Inputs 

Egress 

N.O. Ground 

Door sensor 

N.C. Ground 

Door inhibit 

N.O. Ground 

Proximity reader frequency 

125kHz (EM125) 

Proximity reader sensing distance 

1

1

/

2

" (38mm)

 

IP Rating 

IP66 

Operating humidity 

5~95% Non-condensing 

Operating temperature 

-4°~158° F (-20°~70° C) 

Material 

Faceplate 

1

/

16

" (1.5mm) Stainless steel 

Housing 

5

/

64

" (2mm) Anodized steel, powder paint 

Dimensions 

5

1

/

4

"x7

1

/

16

"x3

3

/

8

" (133x180x85 mm) 

Weight 

3-lb 12-oz (1.7kg) 

 

Specifications:  

Parts List:  

1x  Keypad with steel box 

2x  Keys* 

1x  Security wrench  

4x  Mounting screws 

4x  Mounting screw anchors  1x  Diode 

1x  Mounting template 

1x  Manual 

   

*

No replacement keys available. Please make extra copies for safekeeping. 

 

 
 
 
 

 

Содержание SECO-LARM SLI SK-3133-PPQ

Страница 1: ...n auto adjusting IP66 Weatherproof rating Up to 1 000 user codes and or proximity cards for output 1 100 for output 2 and 100 for output 3 Up to 50 temporary visitor codes Up to 50 duress codes for ou...

Страница 2: ...gress buttons can be connected in parallel as needed Electric Lock N C N O OR OUTPUT RELAY N O Output for Fail secure Lock N C Output for Fail safe Lock N O N O Cathode Diode 1N4004 for DC use only 12...

Страница 3: ...er programming code see pgs 28 29 Programming Instructions Follow the instructions below if the following covers your needs A new master programming code A single 4 digit user code for all users and n...

Страница 4: ...Codes 19 Programming User Codes and Proximity Cards 20 21 Programming Visitor Codes for Output 1 22 Programming Duress Codes 23 24 Programming the Output Mode and Output Timing 25 Programming the Real...

Страница 5: ...Dry contact 50mA 24VDC max Keypad active or alarm output selectable via jumper Keypad illuminates when a button is pressed backlight can be programmed for FULL or AUTO in standby mode IP66 Weatherpro...

Страница 6: ...s N O Ground Door sensor N C Ground Door inhibit N O Ground Proximity reader frequency 125kHz EM125 Proximity reader sensing distance 11 2 38mm IP Rating IP66 Operating humidity 5 95 Non condensing Op...

Страница 7: ...ds Keypad sounds can be programmed ON or OFF see pg 29 Output relay activation sounds can be programmed for 1 second long beep 2 short beeps or OFF see pg 29 Amber LED flashing during standby mode can...

Страница 8: ...wiring hole cover from the back of the keypad housing 5 Install the keypad using the included mounting screws and mounting screw anchors if necessary NOTE If attaching the keypad to a mounting plate s...

Страница 9: ...magnetic contact to monitor if a door is open or closed Connect to ground if not used Output 1 inhibit Output 1 inhibitor N O input connect to Interlock Control of second keypad if needed so that if...

Страница 10: ...O Cathode Diode 1N4004 for DC use only Electric Lock 12 24 VAC VDC Keypad 1 Keypad 2 Inter Lock System Using Two Keypads In this application two keypads are each connected to separate door locks and e...

Страница 11: ...input see Programming the Door Forced Open Warning and Timing pg 30 Door Propped Open Warning The keypad will beep whenever the door is open longer than the programmed time see Programming the Door Pr...

Страница 12: ...urrent does not exceed the maximum rating of 100mA External power supply and isolation relay are strictly necessary in driving high power device such as lights Low power piezo buzzer 1 5K LED OR 12VDC...

Страница 13: ...programmed for one time use or to expire after a set number of hours has passed Duress codes Assigned to specific users as a way to send a silent alert if forced to use the keypad under duress 2 Prox...

Страница 14: ...19 4 Card unique user code The most secure level Each proximity card can be programmed with its own unique user code so that outputs 1 2 or 3 can only be activated if the card and the unique code are...

Страница 15: ...stem restore only when absolutely necessary System restore may take several minutes The amber LED will flash rapidly during thistime Once system restore has been completed the keypad will beep twice t...

Страница 16: ...Visitor codes for output 1 No default must be programmed 22 41 Duress codes for output 1 No default must be programmed 23 24 42 Duress codes for output 2 No default must be programmed 23 24 43 Duress...

Страница 17: ...e only one super user code for the keypad Programming a new super user code will overwrite the previous super usercode The master programming super user common user visitor duress and user codes canno...

Страница 18: ...e output 2 timed or toggle depending on programming 3 Activate or deactivate output 3 timed or toggle depending on programming 4 To toggle operation of output 1 ON or OFF NOTES This function is used t...

Страница 19: ...mmon user code for output 1 2 Program a common user code for output 2 3 Program a common user code for output 3 4 Delete a common user code for output 1 NOTES represents the new common user code which...

Страница 20: ...n be entered instead of a card User code only Type in a 4 to 8 digit user code to activate outputs 1 2 or 3 Card unique user code The most secure level This code is programmed separately for each card...

Страница 21: ...tor duress and user codes cannot be the same Examples 1 Program only a proximity card for user ID 017 for output 1 READ CARD 2 Program a user code 2275 for user ID 010 for output 1 3 Delete a proximit...

Страница 22: ...tor IDs to Up to 50 unique visitor IDS for visitor codes for output 1 Delete all currently programmed visitor codes Valid Duration Set a one time code This code can only be used once by a visitor afte...

Страница 23: ...rammed see Programming User Codes and Proximity Cards pgs 20 21 The duress code should be easy to remember For instance it can be the same as a user s normal user code but with a single digit changed...

Страница 24: ...cannot deactivate the duress output Only a normal user code card super user code or a master programming code can deactivate the duress output NOTE A duress code can also be used in conjunction with...

Страница 25: ...his general formula Output Output Mode and Time Outputs Output 1 Output 2 Output 3 Output Mode and Time Start stop toggle mode In this case the output starts when a user code and or user card is enter...

Страница 26: ...sable time is programmed losing power will cause the keypad to beep 3 times every 5 seconds To deactivate this alert either reset the real time clock or clear the output 1 auto disable time If output...

Страница 27: ...lit during the output 1 auto disable time When programming the output 1 auto disable time use this general formula Program Output 1 Auto Disable Time Start Time End Time Start Time Start time for out...

Страница 28: ...ress output will activate The duress output can be deactivated using any user code or user card or via the super user code to After 5to10successive falseattemptsusingincorrect user codesoruser cards t...

Страница 29: ...activation sounds It does not impact the keypad sounds see Programming the Keypad Sounds above Some of the keypad sounds can be programmed off Keypad audible mode All the keypad s status beeps areena...

Страница 30: ...can be programmed to beep and output to an alarm when a door has been forced open The keypad beep and alarm output can be set to activate for 1 to 999 seconds To Program Door forced open warning OFF...

Страница 31: ...nds if the door is opened In this case if the alarm output is triggered the output either automatically ends at the end of the programmed time or when a user code or super user code is input for outpu...

Страница 32: ...ct with no warning Press and hold the egress button for the programmed delay time until the door is open This prevents accidental opening of the door Hold contact with warning beep Press and hold the...

Страница 33: ...urn ON indicating that the keypad is ready for a new master programming code to be programmed NOTES See Programming the Master Programming Code pg 17 for how to program a new master programming code D...

Страница 34: ...Common user code READ CARD Two short beeps and a rapidly flashing amber LED indicates the card is accepted and the keypad is waiting for the Common user code One Long beep indicates that the door can...

Страница 35: ...s chart to use during setup for future reference User User s Name Output 1 2 or 3 Security Level User ID User Code or Duress Code Card Notes 1 Sample John 1 4 001 Common 001 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 36: ...mited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical...

Отзывы: