background image

These instructions should be read in conjunction with
your System Installation and Operating Instructions
and be retained for future reference.

Introduction

The  SAKP  E  Wirefree  Remote  Keypad  is designed for use

with Response Wirefree Intruder Alarm systems operating

on 433MHz only.

The Wireless Keypad is used to control the system by using

a  four  digit  User  Access  Code.    The  Keypad  incorporates

Panic  and  anti-tamper  protection  features  that  will

immediately  initiate  a  Full  Alarm  condition  when  activated.

Any  attempt  to  open  the  casing  of  the  Keypad  will

immediately  initiate  a  Full  Alarm  condition  even  if  the

system is disarmed, (unless the system is in Service, Test or

Programming  modes).  In  addition  if  a  sequence  of  more

than 16 incorrect key presses is entered the Keypad will be

disabled for the next 1 minute. During this 1 minute duration

the         LED will keep flashing slowly. Consecutively disabled

for  3  times,  the  Keypad  will  emit  the  tamper  signal  to  the

Control Panel.

The  Keypad’s  User  Access  Code  is  independent  from  any

access codes used with a Control Panel.

The Keypad is powered by a 9V PP3 Alkaline battery.  Under

normal operating conditions this will provide an expected life

in  excess  of  1  year.    When  the  battery  level  falls  below  an

acceptable level, the “LOW BATTERY” indicator on the front

of the Keypad will flash. When this occurs the battery should

be replaced as soon as possible

.

Positioning the Keypad

The  Keypad  is  rated  IP44  and  suitable  for  mounting

outdoors.    The  Keypad  should  be  mounted  in  a  position

close  to  the  main  entrance  door  so  that  the  user  access

code can be entered easily.

Ensure  that  the  position  selected  for  the  Keypad  is  within

the effective range of the Siren or Control Panel.

Note: DO  NOT  fix  the  Keypad  to  metalwork  or  locate  the

unit within 1m of metalwork (i.e. radiators, water pipes, etc)

as this could affect the radio range of the Keypad.

Installing and Configuring 
the Keypad

If  you  have  a  system  with  a  Control  Panel,  ensure  it  is  in

Test or Programming Mode. If you have a system without a

Control Panel, ensure that the Siren is in Service mode.

1. Undo and remove the fixing screw from the bottom edge of

the Keypad and remove the wall mounting plate. (Fig. 2).

2. Using  the  mounting  plate  as  a  template,  mark  the

positions of the four fixing holes on the wall.

Note: To  make  the  best  use  of  anti-tamper  protection

you  must  insert  a  wall  plug  and  screw  in  the  specified

hole (as illustrated).

3. Fix the mounting plate to the wall using the screws and

wall plugs provided, (a 5mm hole will be required for the

wall plugs).  Do not over-tighten the fixing screws as this

may distort or damage the mounting plate.

Note: Installing  the  Keypad  against  a  flat  and  smooth

wall  is  of  great  importance  so  as  to  avoid  the  tamper

switch being falsely triggered.

Note: The wall plugs supplied with the product are not

suitable  for  plasterboard  walls,  if  mounting  the  Keypad

on to plasterboard use appropriate wall plugs.

Anti-Tamper

Protection

Fixing

Screw

Fig. 2

Wall Mounting Plate

0

1

2

3

4

5

6

7

8

9

2

1

Arm

Disarm

Part-Arm 1
or Delay Arm

Part-Arm 2
or Delay Arm

Low Battery

Indicator

LED

Transmit

Indicator

LED

Key Pressed

Confirmation

Indicator LED

2

1

Fig. 1     Wireless Keypad Function Guide

433MHz Wirefree Remote Keypad (SAKP E)