About this Manual
This Manual is applicable to Alarm Keypad.
The Manual includes instructions for using and managing
the product. Pictures, charts, images and all other
information hereinafter are for description and explanation
only. The information contained in the Manual is subject to
change, without notice, due to firmware updates or other
reasons. Please find the latest version in the company
website (http://overseas.hikvision.com/en/).
Please use this user manual under the guidance of
professionals.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE
AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND
ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
LOSS OF DATA OR
Trademarks Acknowledgement and other
Hikvision’s trademarks and logos are the properties of
Hikvision in various jurisdictions. Other trademarks and
logos mentioned below are the properties of their
respective owners.
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE
USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS.
HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR
ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER
DAMAGES RESULTING FROM CYBER ATTACK, HACKER
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY
RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK
ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING
THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE
CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL
AND THE APPLICABLE LAW, THE LATER PREVAILS.
Product Information
1
2
4
5
3
Wireless Alarm Keypad
This product and - if applicable - the supplied
accessories too are marked with "CE" and comply
therefore with the applicable harmonized European
standards listed under the RE Directive 2014/53/EU,
the EMC Directive 2014/30/EU, the LVD Directive
2014/35/EU, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For
more information see: www.recyclethis.info
The Input voltage should meet both the SELV (Safety
Extra Low Voltage) and the Limited Power Source
according to the IEC60950-1 standard. Please refer
to technical specifications for detailed information.
Tamper Screw
1
2
3
4
5
2
3
1
1
3
2
1
Control
Panel
Do not mix batteries of
different brands.
Do not mix old and new
batteries.
EN50131-1:2006+A2:2017
EN50131-3:2009E
N50131-5-3:2017
Security Grade 2
Environmental Class II
Present
Beep
Tag Sensed
Present
Remove
Beep
Tag Sensed
Hold 3s,
remove after a beep
1
2
Present
Beep
Tag Sensed
3
System
Armed
Remove
3 failed attempts
(different unregistered
tag or different
password) will cause
the keypad lock (90 s).
Refer to the
Components
and Indication
section for indicator and
buzzer description.
3. Secure the mounting plate on the wall with four supplied screws.
4. Rotate the keypad body clockwise to fasten the body on the plate.
1. Loosen the set screws on bottom of the keypad.
2. Rotate anti-clockwise to remove the mounting plate.
It is required to insert the screw for tamper alarm.
5. Tighten the screw on the bottom to fix the keypad on the mounting
plate and complete the installation.
Enrollment
English
Diagram Reference
Specification
Components and Indication
1
3
Installation
4
5
Power On
2
Power on the security control panel.
Make the control panel enter the
enrollment mode. Press the tamper
switch (on the board) of the keypad. The
partition indicators flashes 4 times when
the keypad is enrolled and ready for
work.
Note: The distance between the security
control panel and the keypad should be
less than 50 cm.
1. Loosen the set screws on bottom of the keypad.
2. Remove the mounting plate.
3. Install four AA batteries according to the polarity mark.
Note: Do not reverse the polarity of the battery.
Check Signal Strength
Enter the signal checking mode by operating on the control panel.
Trigger the tamper alarm.
Power indicator flashes 3 times - Strong Signal
Fault indicator flashes 3 times - Weak Signal
Buzzer
1. Indicator
2. Tag Area
3. TAMPER Switch (on the board)
Power
IndicatorGreen
Blue
Orange
Red
Keypad Backlight White
Keypad locked: flashes 2 times
Turn off if no operation for 5 s, turn on when touched
Normal Battery: Solid green for 2s (keypad waked up)
Low Battery:Flashing green flashes 3 times (keypad waked up)
Weak Signal Strength:Flashes 3 times
Strong Signal Strength:Flashes 3 times
Armed: Related LED flashes once, and light on 2 s while
the keypad is waked up
Disarmed/Alarm Cleared:Related LED flashes twice
Operation failed: Related LED flashes 3 times
Alarm: Related LED flashes 30s
Enrolled and Starts work: 4 LEDs flashes 4 times together
Patrol tag presented: Power and Fault LEDs flashes 2 times
Patrol tag presented: Power and Fault LEDs flashes 2 times
Zone/ Fire Alarm Triggered:Flashes 30s
No Alarm or Alarm Restored:Off
Partition
Indicator
Fault
Indicator
Alarm
Indicator
Present Tag/Tap Key/Armed
Disarmed
Operation Failed
Keypad Tampered
Tag Enrolled
Zone Tampered
Fire Alarm
Beep Beep Beep
Beep Beep Beep Beep Beep
Beep
Beep
Long Beep (30 s)
Long Beep (30 s)
Beep Beep
Formatting
Remove the battery. Hold the TAMPER button (with slend rod) and power
the keypad on at the same time. Release the button when any of the
power, alarm, or fault indicators starts flash. The four indicators flash 4
time after the formatting is completed.
Local Enrollment
APP Enrollment
Operation
Operation
All Partition
1. Enter the user password.
2. Tap the stay/away/disarm key.
Specified
Partition
1. Tap the user password.
2.
Tap the √ key.
3. Enter the partition No.(1/2/3/4).
4. Tap the stay/away/disarm key.
Partition
Keypad
Fire Alarm
Panic Alarm
Confirm
Tasks
1.Enter the user password.
2.Tap the stay/away/disarm key.
Stay/Away Arming
Disarming
Global Keypad
Hold the fire alarm key for 3 s.
Hold the disarming key for 3 s.
Tap the √ key.
1
Away Arming
Other
Operation
Tag Operation
2
Stay Arming
3
Disarming
Delete
Delete the latest key operation
The buzzer indicates the operation status
3. The buzzer indicates the
operation status
5. The buzzer indicates the
operation status
The buzzer indicates the operation status
1. Log in to the
APP Store.
Search for
“Hik-Connect” .Download and install the
client to your phone. Run the client.
2. Power on the security control panel.
3. Log in the client and tap the icon “+”
to add the control panel. Scan the QR
code or input the device serial No.
(serial No. is not supported by device
with 868 RF frequency). to add the
device( in the registration mode).
4. Tap the “+” icon on the device page
to add the peripherals.
RF speed
10.0kbps
/4
.
8
kbps
RF frequency
433
.
6
MHz
/868
.0
5
MHz
RF method
2GFSK
Transmission distance
8
00m (open area)
Po
w
er
10dBm
Tamper-proof
1 tamper s
w
itch, front and rear tamper-proof
Wireless Module
Communicates
w
ith control panel
Card reader
Supports standard IC card
Buzzer
1
Serial port
1, reserved
Indicator
3
status indicators
:
po
w
er (green), fault (red), and alarm (red)
4
par
titi
on indicators
:
armed
/
disarmed (blue)
Backlight
1 group
,
w
hite
Numeric key
10, 0 to 9
Func
ti
on key
6
,
fi
re, a
w
ay arming, stay arming, diarming, dele
ti
ng, and OK
Electrical & Ba
tt
ery
Po
w
er
4
AA Ba
tt
eries
,
3
V DC
,≥
2 years standby
Opera
ti
on humidity
10
%
to 90
%
Opera
ti
on temperature
﹣
10
℃
to
+55
℃
Color
White
/
Black
Installa
ti
on
Wall moun
ti
ng
w
ith scre
w
s
Dimension
Diameter
:
1
3
2 mm (
5
2
"
), Deep
:
2
3
mm(9
"
)
Weight
1
65
g (
w
ithout ba
tt
ery)
Wireless Keypad
RF
Interface and
Component
Others
UD15019B