Sample Applications (Continued):
Sample Applications for Auxiliary Terminals:
•
Door Auto Relock
– The system will immediately relock the door after the door is closed. This
prevents unwanted "tailgate" entries, which can happen if an unauthorized person tries to follow
an authorized person through the door.
•
Interlock Control
– When the door is open, the Interlock Output will give a (-) ground command
to disable the other keypad in an interlock system
•
Door-Forced-Open Warning
– The keypad will beep and activate the alarm output whenever
the door is forced open without using a valid user code, card, or egress input (see
"Programming the Door-Forced-Open Warning and Timing," pg. 30).
•
Door-Propped-Open Warning
– The keypad will beep whenever the door is open longer than
the programmed time (see "Programming the Door-Propped-Open Warning and Timing,"
pgs. 30~31).
•
Door Open Alarm
– The keypad will beep and activate the alarm output whenever the door is
opened without using a valid user code or card (see "Programming the Door Open Alarm and
Timing," pg. 31).
Use a Normally Closed door position
sensor (usually a magnetic contact) on
the door to enable the use of the
following functions:
Door Sensor:
Magnetic
contact
2.
For N.O. locking devices, connect outputs
in parallel with locking device
Door-Hold-Open Mode:
1.
For N.C. locking devices, connect outputs
in series with working device.
Diode 1N4004
(for DC use only)
Diode 1N4004
(for DC use only)
12~24 VDC
Power Supply
Electric lock
Electric lock
DC
DC
12~24 VDC
Power Supply
+
–
+
–
– +
– +