background image

ENFORCER 300C/L 

Installation Manual

ENFORCER 300C/L 

Installation Manual

SECO-LARM U.S.A., Inc.

Page 10

Page 11

ENFORCER 300C/300L 

Connection Diagram

ARM LED
SL-162SR-2

ALARM OUTPUT
2A MAX. MULTI-
TONE SIREN
SH-533L

MAIN POWER

(UNSW12VDC INPUT)

EXTERNAL ACCESSORIES
N.C. GND. INPUT (--)

+12VDC

POSITIVE DOOR SWITCH INPUT (+)

HOOD/TRUNK
SWITCH
SS-061LSN

OR

NEGATIVE HOOD/TRUNK SWITCH INPUT (--)

CHASSIS
GROUND

CHASSIS GROUND (--)

ANTENNA

(DO NOT CUT OR GROUND)

DOOR SWITCH

NEGATIVE DOOR SWITCH INPUT (--)

SIREN OUTPUT

(+12VDC, 2A)

REMOTE
MICROPHONE
SS-051RMP2
(For Glass-
break sensor)

#)

TO OPTIONAL DEVICE (TRUNK
RELEASE, CAR STARTER, ETC.)

PARKING LIGHT RELAY OUTPUT

DUAL CONTACT (+12VDC, 15A)

PARKING LIGHT RELAY OUTPUT

DUAL CONTACT (+12VDC, 15A)

START POSITION SW12VDC, 30A INPUT

STARTER DISABLE RELAY DRY 30A OUTPUT

SENSITIVITY SETTING KNOB FOR GLASS-BREAK SENSOR

PROGRAMMING SW

OFF (PRE-SET)

ON

SW1

ACTIVE ARM

PASSIVE ARM

SW2

ACTIVE LOCK

PASSIVE LOCK

SW3

IGN. AUTO LOCK

NO IGN. AUTO LOCK

SW4

CHIRP

NO CHIRP

SW5

LOCK/UNLOCKK TIME 0.7 SEC. LOCK/UNLOCK TIME 3.5 SEC.

SW6

ASD DISABLE

ASD ENABLE

SW7

NO+ TRIGGER

NC– TRIGGER

SW8

SWITCH SENSING ONLY

C. S. & SWITCH SENSING

(–)3rd CHANNEL OUTPUT (500mA MAX.)

RADIO GROUND

DOOR SWITCH

(PROGRAMMABLE)

* MUST SET PROG. SWITCH

TO  N.O.+ IF NOT USED.

IGNITION SWITCH (SW12VDC INPUT)

MUST HAVE VOLTAGE DURING IGNITION AND START

(--) DOMELIGHT OUTPUT

(300mA max.)

VIA RELAY TO
DOMELIGHT WIRE

(--) 2nd CH. OUTPUT

(300mA max.)

2nd STEP DOOR UNLOCK OUTPUT (300mA max.)

RED

BLACK

ON

+12V or Ground

#)

Parking light polarity select

}

DOOR
LOCK

UNLOCK

GND PULSE

LOCK

+12V PULSE

UNLOCK

+12V PULSE

LOCK

GND PULSE

DOOR LOCK/UNLOCK:
An optional interface relay may be
required on some cars. SR-5201R

WARNING: The door lock outputs
have a maximum loading capacity
of 200mA. Excess current will
cause the outputs to fail and void
warranty.

+12VDC OUTPUT 0.3A MAX.

VELT SWITCH
SS-032MR7-P

#12

#12

RED/
BLACK

BLACK CABE

RED/BLACK

GREY

RED

BROWN

WHITE

WHITE

PURPLE

BLUE/WHITE

BLUE

YELLOW

BLACK/WHITE

GREY/BLACK

BLACK

RED

ORANGE

ORANGE

ORANGE

BROWN/
WHITE

PINK

BROWN/BLACK

PATENTED 2-STAGE, ELECTROMAGNETIC SHOCK SENSOR SS-052BA

* EACH ZONE ADJUSTS INDEPENDENTLY.

NEGATIVE ARMED OUTPUT (BLACK WIRE)

DO NOT CONNECT THE BLACK WIRE OF

THE SS-052BA / SS-052BB SENSOR TO GROUND DIRECTLY.

Содержание 300C

Страница 1: ...e of the alarm and not a problem Check all openings to see which is not closed properly Reprogram to restore chirp Check the connection Check the alarm brain ground for good contact and make sure it is not grounded together with siren Connect these two wires to separate sources of 12VDC Feature not available for parking light systems Wait 4 sec hardwired triggers or 10 sec current sense after armi...

Страница 2: ...propriate wire near the alarm brain while testing the trigger For instance to determine why a door trigger is not TIPS FOR TESTING THE ALARM working probe and test the BLUE WIRE of the 6 pin connector near that connector If the BLUE wire shows when the door is opened then the problem may be caused by the user not arming the alarm correctly or the alarm brain may be defective But if the BLUE wire d...

Страница 3: ...e wires are accidentally pulled by someone servicing the vehicle in the future Remember that wires may shrink or break due to impact heat and so on 3 Do not allow wires to rub against sharp edges which could cause short circuits Use grommets when wires are run through holes in the car body or firewall 4 Protect and hide wires with flexible tubing or by wrapping with electrical tape if possible Ide...

Страница 4: ... eight DIP switches on the alarm brain The various functions are programmed by turning the DIP switches on and off with a pointed object such as an awl Refer to Table 1 to see which functions are controlled by which DIP switches Table 1 Chart of DIP switch programming functions The alarm s main brain which controls all the alarm s functions is very sophisticated and care must be taken when mountin...

Страница 5: ...itively or negatively switched Using a VOM meter test the wires coming from the parking light switch Look for a wire which changes polarity when the parking lights are turned on 1 Positive parking light system If a wire goes to 12VDC when the parking lights are turned on but is not 12VDC with the parking lights turned off this is the parking light wire See fig 3a 2 Negative parking light system If...

Страница 6: ...ty references Ø Ø ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE 15A 3c Dual circuit parking lights ORANGE ORANGE ORANGE ORANGE ORANGE Ø ORANGE ORANGE ORANGE ORANGE ORANGE Ø ORANGE ORANGE ORANGE ORANGE ORANGE 15A 3b Negative single circuit parking lights Connect the polarity select wire to ground Fig 3 Orange wires to flash parking lights O...

Страница 7: ...n unlocked Fig 16 power door lock unlock Positive reversal switching to factory actuators B Positive relay switching to factory actuators fig 15 The factory door lock switch has 3 wires One wire always shows 12VDC The LOCK WIRE becomes 12VDC when the door is locked to pulse a factory relay to lock the doors The UNLOCK WIRE becomes 12VDC when the door is unlocked to pulse a factory relay to unlock ...

Страница 8: ...control knob affects both the 1st and 2nd stage sensitivity 2 Test the pre intrusion 1st stage by lightly shaking a set of keys once This should cause the siren to chirp but not trigger Adjust the sensitivity by turning the adjustment knob clockwise more sensitive or counter clockwise less sensitive 3 Next test the trigger 2nd stage sensitivity by continuously shaking a set of keys firmly inside t...

Страница 9: ...nsor into the alarm brain s 4 pin connector B Set sensitivity 1 Setting the pre intrusion stage Turn the red knob secondary adjuster for trigger output to minimum before adjusting the yellow knob Now lightly tap the vehicle If pre intrusion output is set correctly the yellow LED should come ON the siren chirps parking light flash 5 times but the red LED should not If the yellow LED does not come o...

Страница 10: ...CK UNLOCK TIME 3 5 SEC SW6 ASD DISABLE ASD ENABLE SW7 NO TRIGGER NC TRIGGER SW8 SWITCH SENSING ONLY C S SWITCH SENSING 3rd CHANNEL OUTPUT 500mA MAX RADIO GROUND DOOR SWITCH PROGRAMMABLE MUST SET PROG SWITCH TO N O IF NOT USED IGNITION SWITCH SWITCHED 12VDC INPUT MUST HAVE VOLTAGE DURING IGNITION AND START DOMELIGHT OUTPUT 300mA max VIA RELAY TO DOMELIGHT WIRE 2nd CH OUTPUT 300mA max 2nd STEP DOOR ...