8
6.2 Disconnecting Hydraulic Hoses
Disconnect hydraulic hoses after use as described in the
following steps:
1. Be sure the torque wrench is fully retracted.
2. Verify that the pressure gauge indicates zero (0) psi/bar.
Be certain that all hydraulic pressure is fully relieved before
continuing this procedure. If any pressure remains, relieve
pressure as described in Section 8.3.
3. Remove battery. Refer to Section 7.2.
4. At pump ports “A” and “B”, loosen the threaded collars on
the female couplers. Disconnect hoses from pump.
5. To prevent contamination, place dust caps over couplers.
7.0 BATTERY
The pump is powered by a rechargeable lithium-ion battery. The
pump battery dock is located at the rear of the pump housing.
NOTICE
To prevent accidental pump startup, DO NOT press
the pendant buttons during battery installation or removal
procedures. Also be sure that the trigger lock is in the locked
position as shown in Figure 8.
7.1 Battery Installation
1. Slide the battery down onto the battery dock at the rear of
the pump. See Figure 3.
2. Check that battery locks securely into place.
7.2 Battery Removal
1. Press the release buttons located on each side of the battery.
2. Slide the battery upward and remove it from the pump
battery dock.
NOTICE
To ensure compatibility and proper operation, use only
MILWAUKEE
M28™ lithium-Ion batteries with the pump.
Figure 2, Battery
Figure 3, Battery Installation
7.3 Battery Charge Indicator
NOTICE
New batteries must be charged before use. Refer to
Section 7.1. Also refer to the Milwaukee Electric Tool battery and
charger manual for additional information.
Each battery contains a charge indicator consisting of four
indicator lights. The indicator lights show the approximate
run time remaining before the battery becomes completely
discharged. Press the charge indicator button to display the
lights. The lights will stay lit for two seconds. Refer to the chart in
Figure 4 to determine the level of charge.
4
3
2
1
Figure 4, Battery Charge Indicator
WHEN CHARGE INDICATOR
BUTTON IS PRESSED:
PERCENT
CHARGE:
(APPROXIMATE)
LIGHTS 1, 2, 3 AND 4 ON
78 - 100%
LIGHTS 1, 2 AND 3 ON
55 - 77%
LIGHTS 1 AND 2 ON
33 - 54%
LIGHT 1 ON
10 - 32%
LIGHT 1 BLINKS 4 TIMES
< 10%
LIGHT 1 BLINKS 8 TIMES
0%