Figure 6, Pendant Connection
3. Loosen the threaded ring securing the pendant cable to the
pump pigtail connector.
4. Disconnect the pendant cable from the pigtail connector.
See Figure 6.
9.0 PUMP OPERATION
9.1 Run and Sleep Modes
Press and release any pendant button (or install a charged
battery) to place the pump into run mode. Run mode must be
active before the pump can be operated.
• The pendant LED indicator will illuminate solid green when the
pump is in run mode, indicating that the pump is ready for use.
• The pump will enter sleep mode automatically after 5 minutes
without use. The green LED indicator will turn off when sleep
mode is activated. Sleep mode helps conserve battery power
when the pump is not being used.
• The selected pendant button must be pressed
and
released to
deactivate sleep mode. The pump will remain in sleep mode if
the pendant button is held down and not released.
• A small amount of power is drawn from the battery while the
pump is in sleep mode. The battery will remain charged for
approximately 2 to 4 weeks if the pump remains in sleep mode
and is not operated. However, actual battery life will vary
depending on the battery charge level and condition.
9.2 Operational Modes
The pump has three operational modes:
1. Auto-Cycle Mode (using the pendant)
2. Manual Mode (using the pendant)
3. Manual Mode (using the trigger switch)
These modes are fully described in sections 11, 12 and 13 of this
manual.
Auto-cycle mode can be operated only with the pendant. Manual
mode can be operated using either the pendant or the pump
trigger switch.
Note that the trigger switch provides limited functionality and is
intended only for temporary use in the event that the pendant
becomes lost or damaged.
8.5 Pendant
The pump includes a three-button corded pendant that operates
pump functions. It is connected to the pump with a 20 ft [6 m]
cable. A multi-color LED indicator light communicates pump
status. See Figure 5.
Pendant operation is described in detail in Sections 11
through 13 of this manual.
Figure 5, Pendant Controls
1
2
3
4
1. LED Indicator
(red, green or yellow
depending on pump
function and status)
2. Yellow Button
3. Green Button
4. Red Button
Note:
Refer to Figure 11
for quick reference guide.
8.5.1 Connecting the Pendant
1. If installed, remove the battery from the pump. Refer to
Section 7.2.
2. Connect the pendant cable to the pigtail connector on the
pump shroud. See Figure 6.
3. Using the threaded ring, secure the pendant cable to the
pigtail connector.
8.5.2 Disconnecting the Pendant
1. Verify that the pressure gauge indicates zero (0) psi/bar.
Be certain that all hydraulic pressure is fully relieved before
continuing with the remaining steps of this procedure. If
any pressure remains, relieve pressure as described in
Section 8.3.
2. If installed, remove the battery from the pump. Refer to
Section 7.2.