Document number: ED. 03622.00.001.R04.ENG
Page 98 of 151
ED.02518.00.001.R08.ENG
Page 98
8.2. List of problems and solutions
The table below lists a number of errors and problems which may appear during the use of the
System, together with possible causes and solutions.
Symptom
Possible cause
What to do
…
Main problems
Load value
“–
300
”
displayed
(large negative)
Faulty or loose wiring
Check the wiring
Call Enerpac
All units selected, but none
moves up
Cylinder at end position?
-
One of the hydraulic motors stopped Press the START button [10] on
the Control Panel to restart
Emergency pressed?
Reset the Emergency
All units selected, but only one
moves up
Height measurement was not
zeroed.
Zero the height measurements
using [10] of the RCC.
After switching on the Control
Panel of a Unit, the error
“communication timeout”
is
displayed on the RCC
This is normal behaviour due to time
needed by the starting-up
processes.
Wait for approximately 30
seconds
No display indication after
switching on the RCC
Battery is low
Charge the battery for at least 4
hours
Reports on the display of the RCC
“
Emergency pressed
”
An Emergency button was pressed,
either on one of the unit or on the
RCC.
Reset the emergency
“
Communication timeout
”
Radio disturbed
Use cable connection
“*”
visible behind the RAMs
”
No problem
Appears when the cable
connection is used
“
System not ready
”
Initiation message
Wait a 20 seconds
“
Stroke measurement out of
range
”
Measurement counter defect
Replace the device
Fault in the wiring
Repair the wiring
Height measurement cable snapped Check the cable
“
Load measurements out of
range
”
Sensor defect
Replace the sensor or
contact Enerpac.
Fault in the wiring
Check the wiring
“
Drive sensor error
”
(All Units stop driving)
One of the travelling distance
measuring devices defect
Change the sensor or
contact Enerpac.
If you do not have a
spare sensor, you
might remove all
driving sensors of all Units. The
System will be operational again,
BUT WITHOUT DRIVING
SAFETY! IT IS ON YOUR OWN
RISK.
Too long misalignment between the
Units
The sensor itself slips.
One of the Units is obstructed
“
Engine still
”
Electro motor of the indicated unit is
not running
Push [4] on the Control Panel of
the Unit
Содержание SBL1100
Страница 133: ...Document number ED 03622 00 001 R04 ENG Page 133 of 151 ED 02518 00 001 R08 ENG Page 133 F Drawings for the skid tracks ...
Страница 134: ...Document number ED 03622 00 001 R04 ENG Page 134 of 151 ED 02518 00 001 R08 ENG Page 134 ...
Страница 135: ...Document number ED 03622 00 001 R04 ENG Page 135 of 151 ED 02518 00 001 R08 ENG Page 135 G Drawing of the units ...
Страница 136: ...Document number ED 03622 00 001 R04 ENG Page 136 of 151 ED 02518 00 001 R08 ENG Page 136 ...
Страница 138: ...Document number ED 03622 00 001 R04 ENG Page 138 of 151 ED 02518 00 001 R08 ENG Page 138 ...
Страница 139: ...Document number ED 03622 00 001 R04 ENG Page 139 of 151 ED 02518 00 001 R08 ENG Page 139 I Drawings of the lifting lug ...
Страница 141: ...Document number ED 03622 00 001 R04 ENG Page 141 of 151 ED 02518 00 001 R08 ENG Page 141 ...
Страница 142: ...Document number ED 03622 00 001 R04 ENG Page 142 of 151 ED 02518 00 001 R08 ENG Page 142 ...
Страница 143: ...Document number ED 03622 00 001 R04 ENG Page 143 of 151 ED 02518 00 001 R08 ENG Page 143 ...
Страница 145: ...Document number ED 03622 00 001 R04 ENG Page 145 of 151 ED 02518 00 001 R08 ENG Page 145 ...
Страница 146: ...Document number ED 03622 00 001 R04 ENG Page 146 of 151 ED 02518 00 001 R08 ENG Page 146 ...
Страница 147: ...Document number ED 03622 00 001 R04 ENG Page 147 of 151 ED 02518 00 001 R08 ENG Page 147 ...
Страница 148: ...Document number ED 03622 00 001 R04 ENG Page 148 of 151 ED 02518 00 001 R08 ENG Page 148 ...
Страница 149: ...Document number ED 03622 00 001 R04 ENG Page 149 of 151 ED 02518 00 001 R08 ENG Page 149 ...