background image

ASSEMBLY AND USER MANUAL 
Combi [6 | 12 | 16] & Combi 12 HT 

 

32

 

www.energie.pt

 

 

9.2.

 

Glossary 

 

Esquemas Hidraulicos. 
 

Português 

Inglês 

Francês 

Válvula de Corte 

Shutoff Valve 

Vannes d'arrêt 

Redutora de Pressão 

Pressure Reducing Valve 

Réducteur de pression 

Válvula de Segurança 

Safety valve 

Vanne de sécurité 

Vaso de Expansão 

Expansion Vessel 

Vase d'expansion 

Filtro 

“y”

 

Filter 

Filtre 

Purgador 

Automatic air vent 

Purguer d’air automatic

 

Válvula de Retenção (Anti-retorno) 

Valve (non-return) 

Vanne anti-retour 

Termoacumulador  

Water Tank (DHW) 

Ballon ECS  

Painéis Solares Termodinâmicos 

Thermodynamic Solar Panels 

Panneaux Solaires Thermodynamiques 

Aquecimento Central 

Central Heating  

Chauffage Central 

Entrada de Água Fria 

Cold water inlet 

L’entrée d'eau froide

 

Saída de Água Quente 

Hot Water Outlet 

Sortie d'eau chaude 

Fluxostato 

Flow Switch 

Détecteur de débit 

P1 

Bomba Circuladora 1 

Water circulator 1 

Circulateur d'eau 1 

S1 

Sonda de Temperatura S1 

Temperature probe S1 

La sonde de température S1 

S2 

Sonda de Temperatura S2 

Temperature probe S2 

La sonde de température S2 

S3 

Sonda de Temperatura S3 

Temperature probe S3 

La sonde de température S3 

S4 

Sonda de Temperatura S4 

Temperature probe S4 

La sonde de température S4 

Tamb 

Termóstato Ambiente 

Room Thermostat 

Thermostat ambiance 

Thermostat  Termóstato Exterior 

Ambient Thermostat 

Thermostat exterieur 

B1 

Kit de Resistência (Apoio Circuito 
Hidráulico) 

Electric Heater Kit (Backup Hydraulic 
Circuit) 

Kit de résistance (Circuit Hydraulique) 

B2 

Kit de Resistência (Apoio 
Termoacumulador) 

Electric Heater Kit (Backup Tank) 

Kit de résistance (Ballon ECS) 

Quadro Elétrico 

Electric Board 

Panneau Électrique 

3WV 

Válvula 3 vias 

3 Way Valve 

Vanne à Trois Voies 

COMP 

Compressor 

Compressor 

Compresseur 

EEV 

Válvula de Expansão Eletrónica 

Electronic Expansion Valve 

Vanne d'Expansion Électronique 

HE 

Permutador de Calor 

Heat Exchanger 

Èchangeur de Chaleur 

DF 

Filtro Secador 

Dryer Filter 

Filtre Déshydrateur 

LR 

Depósito de Liquido 

Liquid Receiver 

Réservoir de Liquide 

 
 

Содержание Combi 12

Страница 1: ...www energie pt 1 Assembly and User Manual Thermodynamic Solar System Combi 6 12 16 Combi 12 HT Directives 2006 95 CE Review 1 Version 0 Date 06 01 2015 CENTRAL HEATING DOMESTIC HOT WATER EN...

Страница 2: ...ion 6 4 2 Technical Specifications 7 4 3 Components 8 4 3 1 Combi Block 8 4 3 2 Thermodynamic solar panels 9 5 Installation 9 5 1 Installation Tools required 9 5 2 Thermodynamic Solar Panel 9 5 2 1 Pa...

Страница 3: ...st 21 5 3 7 Vacuum 21 5 3 8 Refrigerant R 407C except Combi 12 HT 22 5 3 9 Fluid Charge 22 5 4 Hydraulic Connections 23 5 5 Temperature Probe 25 6 Control Panel 25 7 Error Messages 27 8 Annexes A Wiri...

Страница 4: ...tain situations indications In this way we seek to ensure any possible problems for the installer or user and assure smooth equipment performance Warning Important Information Indicates any potentiall...

Страница 5: ...ons which must be followed during installation 3 1 Unit inspection The unit was tested and inspected for quality assurance before its dispatch Carefully inspect the equipment components Combi Solar Pa...

Страница 6: ...to move the unit without help Transportation and handling must always be done on vertical It is vital to follow all the warnings and recommendations stated on the packaging boxes 3 5 Unit storage If t...

Страница 7: ...Weight kg 48 96 128 96 Exposed Capture Surface m 9 6 19 2 26 6 19 2 Refrigerant Type R 407C R 407C R 407C R 134a Amount pre charge kg 1 6 2 2 5 2 Test Pressure bar 30 LP Switch Open Value bar 1 0 3 L...

Страница 8: ...heating line It s mandatory to install the safety valve supplied with the system on the heating line Symbol Meaning A Aspiration Line B Liquid Line C DHW Outlet D DHW Inlet E Heating Inlet F Heating...

Страница 9: ...high pressure Vacuum Pump Refrigerant gas loading station or scales Pipe cutter Adjustable spanner Screwdriver Measuring tape Tube bender Tube expander Refrigerant gas cylinder Rotoblock wrench Set of...

Страница 10: ...t of the solar rays on the panel it s best to choose an inclination between 45 and 90 The panels inclination should never be less then 10 However you may install the panels with another inclination in...

Страница 11: ...id at the time of the stoppage of the compressor 5 2 5 Standard Gap of the Panels The position of the panels and the choice of the sides of the connections must be carried out so as to limit the lengt...

Страница 12: ...hand panel A Liquid Line Inlet B Vapour Line Outlet Left A left hand panel is installed on the right front view To this end it has connections on the left side The Solar panel must not be installed o...

Страница 13: ...lability of the installation area the architectonic integration etc In the diagrams below some of the possible positioning layouts of the panels are represented However you may consult in the annex co...

Страница 14: ...way of galvanised M6 screws to prevent corrosion situations The aluminium supports are not supplied with this product The Panels must have a minimum gap of 50cm from the previous and or subsequent pa...

Страница 15: ...ied out The aspiration which allows the collection of the refrigerant fluid in its gaseous state must regroup all the panel aspiration outlets 3 8 as far as the collector This is shown in the figure b...

Страница 16: ...d Position of the piping from the panels Protected from bad weather such as garages cellars attics etc Allow any possible assistance intervention To install the Combi Block is recommended that the sit...

Страница 17: ...ombi Block connections to the panels are supplied with two hermetic valves valves to avoid the penetration of impurities and humidity in the refrigerant circuit wich are already installed according th...

Страница 18: ...2 16 Combi 12 HT 18 www energie pt 5 3 3 Removing the covers 1 Unscrew M6 screws on the top of the unit 2 Move up and pull the front panel 3 Unscrew M6 screws on the lateral as promenor X as picture b...

Страница 19: ...the two thermostats ambiente and external to the elctric box of the Combi Block The power supply cable and the two thermostats should pass on the three electric gland placed on the back of the Combi B...

Страница 20: ...elds and which require the greatest care are carried out at the panels It is necessary to place a damp fabric strip which must envelop the Thermoretractable Joint so that it is fuly protected from hig...

Страница 21: ...trogen from the installation 5 3 7 Vacuum This operation is carried out using one load pipe that is located inside of the unit at the aspiration pipe During this operation the two hermetic valves shou...

Страница 22: ...state we run the risk that one of the components of the fluid will vaporize before the others and hence the installation will have a greater proportion of this component This is why the installation...

Страница 23: ...temp at the panels This values are estimated for water return temperatures of between 25 30 C Exterior Temperature Aspiration Pressure C bar 0 1 2 5 1 6 10 2 2 15 2 9 20 3 6 25 4 5 30 5 5 You may not...

Страница 24: ...with the existing equipment Firstly preferably choose heat emitters with a large exchange surface radiant flooring radiators convectors ventilo convectors as they allow distribution at a low temperatu...

Страница 25: ...ergie Combi System takes the form of a console whereby several operating settings can be configured such as Water outward and return temperature Temperature differentials Timers Typical ground plans o...

Страница 26: ...6 12 16 Combi 12 HT 26 www energie pt For more information about the electronic panel please read the Energie Electronic Panel manual that is supplied with the equipment ERROR Code System Status Date...

Страница 27: ...ruction of refrigerant circuit e g Humidity Low pressure switch damaged Er04 HP High pressure system doesn t work Fluid overcharge Check circuit pressure with manometers High pressure switch damaged P...

Страница 28: ...ASSEMBLY AND USER MANUAL Combi 6 12 16 Combi 12 HT 28 www energie pt 8 ANNEXES A WIRING DIAGRAM 8 1 Combi System 220 240 Vac 1 N 50 Hz...

Страница 29: ...ASSEMBLY AND USER MANUAL Combi 6 12 16 Combi 12 HT www energie pt 29 8 2 Combi System 400 420 Vac 3 N 50 Hz...

Страница 30: ...sion Valve D tendeur Rc Resist ncia de C rter Crankcase Heater R sistance de carter SY250 Controlador Controller Contr leur HP Press stato de Alta High Pressure Switch Pressostat haute pression LP Pre...

Страница 31: ...ASSEMBLY AND USER MANUAL Combi 6 12 16 Combi 12 HT www energie pt 31 9 ANNEXES B INSTALLATION 9 1 Plan...

Страница 32: ...tor 1 Circulateur d eau 1 S1 Sonda de Temperatura S1 Temperature probe S1 La sonde de temp rature S1 S2 Sonda de Temperatura S2 Temperature probe S2 La sonde de temp rature S2 S3 Sonda de Temperatura...

Страница 33: ...used or assembled in accordance with manufacturer instructions or if there has been any form of intervention by unauthorized technicians has the appearance of modifications and or if the series number...

Страница 34: ...ASSEMBLY AND USER MANUAL Combi 6 12 16 Combi 12 HT 34 www energie pt...

Страница 35: ...Combi 6 12 16 Combi 12 HT www energie pt 35 ENERGIE EST LDA Zona Industrial de La ndos Lote 48 4570 311 La ndos P voa de Varzim Portugal Phone 351 252 600 230 Fax 351 252 600 239 E Mail energie energ...

Отзывы: