5.2.2.
Inclination
The inclination angle of the sun rays with regard to the horizontal varies in accordance with the seasons of the year.
In Winter, at the Zenith, the solar rays form an angle of 20º to 40º with regard to the horizon. In Summer the angle
is between 60º and 80º.
To get the most out of the solar rays on the panel, it’s best to choose an
inclination between 45º and 90º.
The panels inclination should never be less then 10°.
However, you may install the panels with another inclination in certain situations.
5.2.3.
Distance
The maximum distance between the panels and the Combi Block depends on certain factors such as the
equipment model, the no. of curves, the piping diameter etc.
However, we would recommend that the distance should not exceed the
20m
.
For Installations with a distance greater than those indicated must contact the Technical Dept.