![Energic Plus AR-TOP Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/energic-plus/ar-top/ar-top_user-manual_2409954029.webp)
ENERGIC Plus
AR-TOP [V.140 – January 2011]
USER'S MANUAL
___________________________________________________________________________________________________________________________________________________
12
Charge completed successfully.
Equalize completed successfully.
GROUP 2:
MANUAL STOP
11
Charge stopped manually, during a generic cooling state
20
Charge stopped manually, before to reach the gassing voltage.
21
Charge stopped manually, during the finishing charge.
22
Charge stopped manually, during eq.
23
Charge stopped manually, during refresh.
24
Charge stopped manually, during desulphation.
GROUP 3:
BATTERY DISCONNECTED
30
The battery has been disconnected before the begin of the charge, while the charger was
waiting for the programmed Start Time window.
31
The battery has been disconnected during the first part of the charge, before to reach the
gassing voltage.
32
Successful Opportunity charging cycle.
The battery reached the gassing point, the charger entered in stand-by mode waiting for the
Full Charge/Overcharge time window, and at that point the battery has been disconnected.
33
The battery has been disconnected during the finishing charge, while it was cooling between
two charging pulses.
34
The battery has been disconnected during the finishing charge, while it was receiving a
charging pulse.