PARAMETER 12:
WBM ENABLE
Programmable values: Enabled, Disabled, Optional
Default value:
Disabled
NOTES:
This parameter sets the operation of the charger with the Wireless Battery Identification module WBM
(optional). Three different operating modes are selectable.
Enabled:
When a battery is connected, the charger establishes a communication with the WBM and uses
the information stored into the WBM to optimize the charge cycle.
Only batteries with WBM installed and properly configured will be charged!
Disabled:
The communication of the charger with WBMs is disabled, and any battery (with correct
voltage) will be charged.
Optional:
When a battery is connected, the charger tries to establish a communication
with the WBM.
If a WBM is found, it's used to optimize the charge cycle and to add the battery ID tag on the
charge history log. If a WBM is not found, the battery will be charged anyway.
PARAMETER 13:WIRED IP ADDRESS RS-485/RESET/TEST WIRELESS
Programmable values: 1 to 254 (Hexadecimal)
Default value:
1