Wallbox Adspace - Assembly manual
8 - 2021
Variant 3
Variant 4
Charging module - Type 2 socket
with RCM B 6 mA DC
Charging module - Type 2 socket
with RCM B 6 mA DC
Type 2
socket
Type 2
socket
Charging module - Type 2 socket
with RCM B 6 mA DC
Charging module - Type 2 socket
with RCM B 6 mA DC
Type 2
socket
Type 2
socket
MID METER
MID METER
MID METER
MID METER
Housing
Housing
METER
METER
fuse
fuse
Fig. 14: Diagrams of connection types 2/2.
5.1.1.
Standard power connection
INFO
For both charging sockets to function in Ene-
lion Wallbox Adspace the voltage must be sup-
plied to the electrical connection clamps of both
charge controllers. The steps described below
should be applied to the terminals of both charg-
ing sockets.
1. Run the left socket power supply cable along the
bottom part of the device below the backlight
shield.
2. Prepare the power supply cable.
Remove 200 mm of the main insulation off the
power supply cable.
Terminate the individual
wires of the cable with fork (M4 or M5 size) or
sleeve terminals.
3. Insert the power supply cables into the terminals.
Fig. 15: Connection using fork terminals.