Service the power generator ESE 604 (ES) DHG DIN
74
ESE 604 DHG (ES) DIN
Status: October 2018
6.2.2
Replacing the starter battery
1.
Unscrew the battery holder
(Fig. 6-3-(1))
.
2.
Remove the battery
(Fig. 6-3-(2))
from the battery compart-
ment.
3.
Unscrew the battery cable. Push the protective terminal
caps back for this purpose and loosen the screws. Always
disconnect the cable from the NEGATIVE terminal first
and then disconnect the cable from the POSITIVE termi-
nal.
Battery is disconnected.
Fig. 6-3: Replacing the battery
4.
Prepare a new battery.
5.
The battery cables must first be screwed onto the
POSITIVE terminal, then onto the NEGATIVE-terminal
and then put on the terminal caps.
6.
Put the battery back into the battery compartment.
7.
Put the battery holder
(Fig. 6-3-(1))
back on.
The battery has been replaced.
WARNING!
A highly explosive electrolytic gas mixture develops
from gassing when charging batteries.
Flames, sparks, an open light and smoking are prohib-
ited.
Avoid sparks when handling cables and electrical de-
vices, as well as electrostatic discharge.
Avoid short-circuits.
Содержание ESE 604 DHG DIN
Страница 11: ...General information Status at October 2018 ESE 604 DHG ES DIN 11 Notes...
Страница 26: ...General Safety Regulations 26 ESE 604 DHG ES DIN Status October 2018 Notes...
Страница 33: ...Description of the power generator ESE 604 DHG DIN Status at October 2018 ESE 604 DHG ES DIN 33 Notes...
Страница 49: ...Operate power generator ESE 604 DHG DIN Status at October 2018 ESE 604 DHG ES DIN 49 Notes...
Страница 81: ...Troubleshooting Status at October 2018 ESE 604 DHG ES DIN 81 Notes...
Страница 85: ...Technical specifications Status at October 2018 ESE 604 DHG ES DIN 85 Notes...