11 Appendix
TopCal S CPC 300
144
EHauser
PARAM
Editing service code
0000
(0...9997)
Editing specialist
code
0000
(0...9997)
C07-CPM153xx-19-06-08-en-006.EPS
Editing Damping
pH/ORP: 00s
Temperature: 00s
Display format
pH 00.00
pH 00.0
(only pH)
Select temperature
display
°C
° F
Select
Current output conf.
Current output 1
Current output 2
Relay function
Acc. NAMUR off
Chemoclean off
available for limit/
controller 5
Select
Current output 1/2
pH/mV Input 1
pH/mV Input 2
Temperature Input 1
Temperature Input 2
Delta Input 2-1
Select NAMUR
Active open
Active closed
Select Limit
Active open
Active closed
Note if selection is
changed:
Caution! Conf. will
be reset.
(Cancel with
PARAM)
Select Controller
Active open
Active closed
Select Active
mode
Active on
Active pulse
Note field:
Chemoclean is
always NO.
Select
Output range 1/2
0 … 20 mA
4 … 20 mA
Warning if
»Min« is selected
for current range
0...20mA
Output type 1/2
linear
table
Edit number
0/4 mA: 02.00pH
(000.0°C)
20 mA: 12.00pH
(100.0°C)
Info field
Current output 1/2
linear active
Edit table points
pH mA
00.00 04.00
(000.0°C)
Enter number
of table points
01
(1...10)
Select
Temp.comp. sensor
Temp.comp.
process
(only pH)
Select input
Temp.sensor input 1
Temp.sensor input 2
(not with single loop)
Select temp. comp.
K1/K2
ATC Input 1
ATC Input 2
MTC
MTC + Temp.
(only pH)
Edit MTC temp.
K1/K2
025.0°C
(-20.0...150.0°C)
(only pH,MTC)
Temperature
measurement K1K/2
off
on
(only Redox)
Temp.sensor
Pt 100
Pt 1000
NTC 30k
Actual temp. value
for Offset K1/K2
25.0°C
(20.0...30.0°C)
Edit Offset K1/K2
0.0°C
(-5.0...5.0°C)
Select
Select table
Create table
Reference
temperature
Select medium K1
Medium 1
Medium 2
Medium 3
no
Select medium K2
Medium 1
Medium 2
Medium 3
no
Select medium
Medium 1
Medium 2
Medium 3
Reference
temperature in
laboratory meas.
25.0°C
(-20.0...150.0°C)
Select
Sensor input
Display
Access codes
Current output
Relays
Temperature
)
(Alarm,
Hold,
Calibration see below
Select operating
mode
pH
Redox/ORP: mV
Redox/ORP: %
Select measuring
principle
Single loop input 1
Single loop input 2
Dual input 1+2
Select dual input
Dual channel
Delta
Redundancy
(only dual input)
Editing tag number
(0...9; A...Z)
Select electrode
type 1
Glass electrode 7.0
Glass electrode 4.6
Antimony
IsFET
(only pH)
Select electrode
type 2 (only pH,
dual input)
Glass electrode 7.0
Glass electrode 4.6
Antimony
IsFET
Select
Sensor ground
solution ground
no solution ground
Date+time
Weekday Mo
Day 30
Month 04
Year 01
Time 12:00
Editing Contrast
with + and - keys
Select language
English E
Deutsch D
Francais F
Italian I
Spanish ES
»Return field«:
press the PARAM
key to return to
these highlighted
fields.
= Code entry required
Back to
return field
Edit pairs
°C pH
000.0 00.00
Query
Ok
Delete pair
(then back to the
edit pairs)
Note field
Table status
invalid table
--> back
Valid table
--> to return field
Edit table points
00
(2...10)
Back to
return field
PARAM
Set up 1
Set up 2
Manual Operation
First Set up