TH53, TH54 and TH55

4

Hauser

maintenance using universal device configuration tools like FieldCare, DeviceCare or

FieldCommunicator 375/475. For more information, see the Technical Information.

PROFIBUS

®

 PA head transmitters

Universally programmable head transmitter with PROFIBUS

®

 PA communication. Conversion of

various input signals into digital output signals. High accuracy over the complete ambient

temperature range. The configuration of PROFIBUS PA functions and of device-specific parameters is

performed via fieldbus communication. For more information, see the Technical Information.

FOUNDATION Fieldbus™ head transmitters

Universally programmable head transmitter with FOUNDATION Fieldbus™ communication.

Conversion of various input signals into digital output signals. High accuracy over the complete

ambient temperature range. All transmitters are released for use in all important process control

systems. The integration tests are performed in Hauser's "System World". For more

information, see the Technical Information.
Advantages of the iTEMP transmitters:

• Dual or single sensor input (optionally for certain transmitters)

• Pluggable display (optionally for certain transmitters)

• Unsurpassed reliability, accuracy and long-term stability in critical processes

• Mathematical functions

• Monitoring of the thermometer drift, sensor backup functionality, sensor diagnostic functions

• Sensor-transmitter matching for dual sensor input transmitters, based on Callendar/Van Dusen

coefficients

Field transmitter

Field transmitter with HART® or FOUNDATION Fieldbus™ communication and backlit display. Can

be read easily from a distance, in sunlight and at night. Large measurement value, bargraph and

fault indication displayed. Benefits are: dual sensor input, highest reliability in harsh industrial

environments, mathematic functions, thermometer drift monitoring and sensor back-up

functionality, corrosion detection.

Galvanic isolation

Galvanic isolation of Hauser iTEMP transmitters

Transmitter type

Sensor

TMT181 PCP

Û = 3.75 kV AC

TMT182 HART®

U = 2 kV AC

TMT162 HART® Field transmitter

U = 2 kV AC

TMT82 HART®

U = 2 kV AC

TMT84 PA

TMT85 FF

In applications where fast response time is needed, grounded thermocouples are recommended.

This thermocouple design may cause a ground loop. This can be avoided by using iTEMP

transmitters with high galvanic isolation.

Содержание TH53

Страница 1: ...Field transmitter Temperature field transmitters with HART or FOUNDATION Fieldbus protocol for highest reliability in harsh industrial environments Backlit display with large measured value bargraph...

Страница 2: ...4 flanged thermowell TH53 tilted threaded thermowell RMS621 Heat exchange process A0027371 EN 1 Application example Calculation of heat quantity which is emitted or absorbed by a water flow in a heati...

Страница 3: ...y to reduce the above limits in order to achieve adequate service Thermocouples with 316 SS sheath and assemblies with 316 SS thermowells are rated for a maximum temperature of 927 C 1700 F Output Out...

Страница 4: ...ual or single sensor input optionally for certain transmitters Pluggable display optionally for certain transmitters Unsurpassed reliability accuracy and long term stability in critical processes Math...

Страница 5: ...26046 Head mounted transmitter TMT8x dual input 1 2 7 6 5 4 3 1 2 7 6 5 4 3 Sensor input 2 Sensor input 1 Bus connection and supply voltage Display connection TC TC A0012699 EN Field mounted transmitt...

Страница 6: ...drop occurs Connection data Maximum continuous voltage rated voltage UC 42 VDC Nominal current I 0 5 A at Tamb 80 C 176 F Surge current resistance Lightning surge current D1 10 350 s Nominal discharg...

Страница 7: ...onstantan X Red J JP Iron X White Brown JN Copper 45 nickel constantan X Red K KP Nickel 10 chromium X Yellow Brown KN Nickel 5 aluminum silicon 1 X Red T TP Copper X Blue Brown TN Copper 45 nickel co...

Страница 8: ...32 to 2300 F 2 2 or 0 75 1 1 or 0 4 T 0 to 370 C 32 to 700 F 1 or 0 75 0 5 or 0 4 N 0 to 1260 C 32 to 2300 F 2 2 or 0 75 1 1 or 0 4 For measurement errors in F calculate using equation above in C the...

Страница 9: ...d the process to be measured must be taken into account e g flow velocity process pressure Installation possibilities Pipes tanks or other plant components Minimum immersion length per ASTM E644 T 0 0...

Страница 10: ...itter and display 20 to 70 C 4 to 158 F With mounted field transmitter Without display 40 to 85 C 40 to 185 F With display and or integrated overvoltage protection module 40 to 80 C 40 to 176 F SIL mo...

Страница 11: ...mowell tapered 2 TH53 threaded thermowell stepped 3 TH53 socket weld thermowell tapered 4 TH53 TH54 extension nipple union nipple NUN without thermowell 5 TH55 extension hex nipple without thermowell...

Страница 12: ...2 3 mm in 342 9 mm 13 5 in 1 socket weld Stepped standard duty 22 3 mm in Tapered heavy duty 25 4 mm 1 in 419 1 mm 16 5 in weld in Tapered heavy duty 26 6 mm 1 050 in 571 5 mm 22 5 in 1 weld in Tapere...

Страница 13: ...er response times than an ungrounded junction of similar sheath diameter Grounded junctions should not be used with Type T thermocouples due to the copper wire For a reliable temperature reading of gr...

Страница 14: ...high corrosion resistance in chlorine based and acidic non oxidizing atmospheres through the addition of molybdenum e g phosphoric and sulfuric acids acetic and tartaric acids with a low concentratio...

Страница 15: ...NUN NPT external thread 101 6 mm 4 in 177 8 mm 7 in Housing Terminal heads All terminal heads have an internal shape and size in accordance with DIN EN 50446 flat face and a thermometer connection wi...

Страница 16: ...tion standard version IP69K NEMA Type 4x encl Degree of protection version with display window IP66 68 NEMA Type 4x encl Temperature 50 to 130 C 58 to 266 F without cable gland Material stainless stee...

Страница 17: ...thread NPT with adapter for NPT M20x1 5 Protective assembly connection NPT Color white Weight approx 100 g 3 5 oz Ground terminal only internal via auxiliary terminal LCAUTION Potential electrostatic...

Страница 18: ...nnector 7 8 16 UNC on FOUNDATION Fieldbus connector Ambient temperature 40 to 150 C 40 to 300 F Degree of protection IP67 Wiring diagram 1 3 2 4 A0006023 PROFIBUS PA Pos 1 gray shield Pos 2 brown Pos...

Страница 19: ...urces In the Product Configurator on the Endress Hauser website www endress com Click Corporate Select your country Click Products Select the product using the filters and search field Open product pa...

Страница 20: ...ireless connection of field devices The WirelessHART adapter can be easily integrated into field devices and existing infrastructures offers data protection and transmission safety and can be operated...

Страница 21: ...a the Internet www endress com lifecyclemanagement On CD ROM for local PC installation FieldCare SFE500 FDT based plant asset management tool from Endress Hauser It can configure all smart field units...

Страница 22: ...eparation of 4 to 20 mA standard signal circuits Has bidirectional HART transmission and optional HART diagnostics if transmitters are connected with monitoring of 4 to 20 mA signal or HART status byt...

Страница 23: ...TMT84 TI00138R 09 FOUNDATION Fieldbus TMT85 TI00134R 09 Field transmitter TMT162 HART 5 PROFIBUS PA and FOUNDATION Fieldbus TI00086R 09 EN TMT162 HART 7 and SIL certification TI01344T 09 EN TMT142 HA...

Страница 24: ...www addresses endress com...

Отзывы: