Installation
Proline Promag H 200
22
Hauser
1
3
2
4
2
A0002651
å
8
Installing ground rings
1
Hexagonal-headed bolts (process connection)
2
O-ring seals
3
Ground ring or plastic disk (spacer)
4
Sensor
1. Loosen the 4 or 6 hexagonal headed bolts (1) and remove the process connection from the
sensor (4).
2. Remove the plastic disk (3), including the two O-ring seals (2).
3. Place first seal (2) in the groove of the process connection.
4. Place the metal ground ring (3) on the process connection.
5. Place the second seal (2) in the groove of the ground ring.
6. Finally, mount the process connection on the sensor again. With plastic process
connections, note the max. torques for lubricated threads: 7 Nm (5.2 lbf ft)
6.2.4
Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned: