Proline Promag 55 PROFIBUS PA
Installation
Hauser
35
3.3.5
Installing the wall-mount housing
There are various ways of installing the wall-mount transmitter housing:
• Mounted directly on the wall
• Installation in control panel (with separate mounting kit, accessories)
• Pipe mounting (with separate mounting kit, accessories)
"
Caution!
• Make sure that the permitted ambient temperature range is observed (see nameplate or
Page 121). Install the device at a shady location. Avoid direct sunlight.
• Always install the wall-mount housing in such a way that the cable entries are pointing down.
Mounted directly on the wall
1.
Drill the holes as illustrated.
2.
Remove the cover of the connection compartment (a).
3.
Push the two securing screws (b) through the appropriate bores (c) in the housing.
– Securing screws (M6): max. Ø 6.5 mm (0.24")
– Screw head: max. Ø 10.5 mm (0.4")
4.
Secure the transmitter housing to the wall as indicated.
5.
Screw the cover of the connection compartment (a) firmly onto the housing.
a0001130-ae
Fig. 27:
Mounted directly on the wall
a
b
c
c
90 (3.54)
35 (1.38)
192 (7.56)
81.5
(3.2)
mm (inch)