Liquiphant M/S with electronic insert FEL58 + Nivotester FTL325N
Hauser
17
Permitted devices types
The details pertaining to functional safety in this manual relate to the device versions listed below
and are valid as of the specified firmware and hardware versions. Unless otherwise specified, all the
following versions can also be used for protective systems. A modification process according to
IEC 61508 is applied for device changes.
Valid device versions for safety-related use: Liquiphant M FTL50, FTL50H, FTL51, FTL51H, FTL51C
Ordering feature Designation
Option
010
Approval
All
020
Process connection
All
030
Probe length; type
All
040
Electronics; output
8
FEL58; SIL NAMUR+test button (L-H signal)
050
Housing; cable entry
All
060
Additional option
All
570
Service
All
580
Test, certificate
All
600
Sensor design
All
895
Marking
All
• Valid firmware version: 01.00.01 and higher
• Valid hardware version: 01.01 and higher
Valid device versions for safety-related use: Liquiphant S FTL70, FTL71
Ordering feature Designation
Option
010
Approval
All
020
Process connection
All
030
Probe length
All
040
Electronics; output
8
FEL58; SIL NAMUR+test button (L-H signal)
050
Housing; cable entry
All
060
Additional option
All
070
Application
All
570
Service
All
580
Test, certificate
All
600
Sensor design
All
895
Marking
All
• Valid firmware version: 01.00.01 and higher
• Valid hardware version: 01.01 and higher