Proline Promass 80
Technical data
Hauser
81
Zero point stability Promass F (high-temperature version)
Example for max. measured error
A0013424
Fig. 39:
Max. measured error in % o.r. (example: Promass F, DN 25)
Flow values (example)
Repeatability
Design fundamentals
82.
o.r. = of reading; 1 g/cc = 1 kg/l; T = medium temperature
• Mass flow and volume flow (liquid): ±0.05% o.r.
• Mass flow (gas): ±0.25% o.r.
• Density (liquid): ±0.00025 g/cc
• Temperature: ±0.25 °C ± 0.0025 · T °C; (±0.5 °F ± 0.0015 · (T–32) °F)
DN
Zero point stability Promass F (high-temperature version)
[mm]
[inch]
[kg/h] or [l/h]
[lb/min]
25
1"
1.80
0.0661
50
2"
7.00
0.2572
80
3"
18.0
0.6610
0
±0.5
±0.2
±1.0
[%]
0
2
4
6
8
10
12
14
16
18
t/h
Turn down
Flow
Maximum measured error
[kg/h] or [l/h]
[lb/min]
[% o.r.]
500 : 1
36
1.323
1.5
100 : 1
180
6.615
0.3
25 : 1
720
26.46
0.1
10 : 1
1800
66.15
0.1
2 : 1
9000
330.75
0.1
o.r. = of reading; Design fundamentals