To avoid this, the sensor values at the transmitter can be set to
HOLD
for the duration of
sampling. In this case, sampling is performed as follows:
1. Set the sensor measured values on the transmitter to
HOLD
.
Follow the Operating Instructions for the transmitter.
2. Carefully open the sampling valve and rinse for a few seconds.
Collect this quantity of liquid in a suitable vessel and discard.
3. Take a sample in a suitable vessel.
4. Close the sampling valve securely.
5. Cancel the
HOLD
status of the sensor measured values on the transmitter.
6. Check the flow setting/function of the assembly and readjust if necessary.