Magical Balancer
1
Warning sign and Precautions for Handling
11
1-2-2
Installation
DANGER
Be sure to install the stoppers on the ends of the traverse and travel rails.
Ensure that the location where the Magical Balancer is installed has sufficient
strength.
WARNING
The installation must be performed by professionals or a person who has expertise.
Do not install the Magical Balancer in a location outside the specified environment,
such as a location where the balancer is exposed to rain or water.
Do not connect the ground wire to the following.
Gas and hydraulic piping: Danger of explosion or catching fire.
Telephone line and lightning rod: Danger in case of lightning.
Water pipe partially made of plastic in the middle: Does not serve as the ground.
Danger of electric shock. Implement a D class grounding construction.
In addition to the grounding, install an earth leakage breaker on the electric circuit.
Be sure to attach an auxiliary wire rope to the Magical Balancer.
CAUTION
Do not operate the product on the floor (placed horizontally).
Do not operate the Magical Balancer with slack in its wire rope.
Always suspend the balancer when operating it.
1-2-3
Air supply pressure and voltage
WARNING
Operate the Magical Balancer with an air supply pressure less than 0.7 MPa.
Use the operating voltage and current within their ratings
(
AC100V/0.7A
・
AC115V/0.7A
・
AC240V/0.4A
)
CAUTION
Do not use a lubricator (oiler) for the air supply line of the Magical Balancer.
Do not use any type of lubricating oil, because it may cause a malfunction in the
control module as well as damage to the internal parts.
Be sure to install a filter and a regulator.