Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-05r1 DAG 3.6E Card User Manual
Copyright, all rights reserved.
19
Revision 6. 8 August 2005.
4.0 RUNNING DAG CARD DATA CAPTURE SOFTWARE
Introduction
For a typical measurement session, the
scripts/dag36estart
script is
edited and used to operate the cards directly.
In this chapter
This chapter covers the following sections of information.
•
Starting DAG Card Capture Session
•
High Load Performance
4.1 Starting DAG Card Capture Session
Description
Capture settings are set for both cards in use. The various tools used for
data capture are in the
tools
sub-directory.
For a typical measurement session, first move to the
dag
directory, load
the driver, then load the Xilinx receive image to each DAG. For example,
with one DAG 3.6E card installed:
tools/dagrom -rvp –d dag0 -f xilinx/dag36epci-erf.bit
tools/dagld -x –d dag0 –f xilinx/dag36epp-erf.bit
The integrity of both DAG cards physical layer is then set and checked.
Process
Starting a data capture session is described in the following process.
Process Description
Load directory.
Move to
dag
directory and load driver, and load
Xilinx receive image to each DAG.
For example, with one DAG 3.6E card installed:
tools/dagrom -rvp –d dag0 –f
xilinx/dag36epci-erf.bit
tools/dagld -x –d dag0 –f
xilinx/dag36epp-erf.bit
Set physical layer
integrity.
Set and check the integrity of the physical layer
of the DAG LED status.
Continued on next page