Endace Measurement Systems Limited
http://www.endace.com
EDM01.05-05r1 DAG 3.6E Card User Manual
Copyright, all rights reserved.
16
Revision 6. 8 August 2005.
3.5 Inspect Interface Statistics
, continued
Port A card
locked to
100Base-T
stream
The following is an example for Port A of a card locked to a 100Base-T
stream.
dag@endace:~$ dagthree -d dag0 -asi
A:
Spd SD Lnk Lck Neg FC IS HS
PE RF JB
100 1 1 1 1 0 0 0
0 0 0
100 1 1 1 1 0 0 0
0 0 0
100 1 1 1 1 0 0 0
0 0 0
100 1 1 1 1 0 0 0
0 0 0
Network link
fault corrective
action
A network link fault problem is indicated if any other bits are numeral 1.
This may or may not be related to addition of the DAG 3.6E card.
All cabling is checked, ensuring that runs are not too long and plugs
firmly clipped into connectors.
Error condition detectors or counters on the Ethernet equipment are
checked.
Corrective action can also be performed by removing the DAG card from
the link.