9 Fibre blowing
9.12.3 Flow meter Kit (7778)
The flow meter kit contains the flow meter, air stones and air hose connectors.
Reading the Flow meter
The reading from the fl ow meter is taken from the top of the weight as shown below.
Tube Connection to Air hose
This is needed when either testing a system or blowing out a fi bre unit.
1. Push air hose connector A into
the hose.
2. Attach the primary m/d to the
8mm-5mm reducer.
3. Push the two together.
Correct reading (25 litres per minute)