background image

SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL

eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal

23-15-30

TC-2

8 MAY 09

C. Front Panel LEDs ............................................................................................................  1-7

D. Fault Conditions ...............................................................................................................  1-8

E. HSD-Xi  Maintenance Port...............................................................................................  1-8

8. User Interfaces........................................................................................................  1-9

A. Ethernet Data Interface....................................................................................................  1-9

B. ISDN Interface .................................................................................................................  1-9

C. Maintenance Port Interface..............................................................................................  1-9

(1) End User Access: Level 1 .........................................................................................  1-10

(2) Field Representative Access: Level 2 .......................................................................  1-10

9. Initiated Self-Test..................................................................................................  1-10

SYSTEM OPERATION

1. Registering and Activating Terminals ..................................................................  2-1

A. Preparing Terminal Information .......................................................................................  2-1

(1) Obtaining ISNs ............................................................................................................  2-1

(2) Identifying the Swift64 Service Terminal Type ............................................................  2-1

B. Choosing Service Providers ............................................................................................  2-2

C. Registering Terminals ......................................................................................................  2-2

INSTALLATION

1. Advisories ...............................................................................................................  3-1

2. Pre-Installation Inspection.....................................................................................  3-1

3. Mechanical Installation ..........................................................................................  3-1

4. Electrical Installation..............................................................................................  3-2

A. Cabling Notes ..................................................................................................................  3-2

B. Source/Destination Identification (SDI) ............................................................................  3-3

C. Maintenance Port Interface..............................................................................................  3-3

D. Remote Status Panel .......................................................................................................  3-3

E. System Mode Strapping ..................................................................................................  3-4

F. HSD-Xi Input/Output Strapping........................................................................................  3-5

G. User Interfaces ................................................................................................................  3-5

Содержание eNfusion 1252-A-4100-01

Страница 1: ...Description Installation and Maintenance Manual MN 1252 42003 Revision B00 This document provides procedures for the equipment listed below Model PN eNfusion HSD Xi High speed Data Terminal 115 V ac 1252 A 4100 01 eNfusion External Subscriber Configuration Module ESCM 1252 A 4120 01 ...

Страница 2: ...n this product is protected by intellectual property rights including patent rights copyrights and trade secrets of Digital Voice Systems Inc This voice compression Technology is licensed solely for use within an INMARSAT satellite communications system Our products are under continuous research and development Any information may therefore be changed without prior notice EMS SATCOM reserves the r...

Страница 3: ...rvey and send to EMS SATCOM at EMS SATCOM 400 Maple Grove Road Ottawa ON K2V 1B8 E mail techdocs emssatcom com Date Comments Publication information Customer information Comments and suggestions Publication number MN 1252 42003 Publication title eNfusion HSD X and HSD Xi High speed Data Terminal System Description Installation and Maintenance Manual Latest issue date 8 MAY 09 Document revision B00...

Страница 4: ...23 15 30 CR 2 8 MAY 09 Blank Page ...

Страница 5: ... HSD Xi High speed Data Terminal 23 15 30 RR 1 8 MAY 09 RECORD OF REVISIONS When revisions are received insert revised pages record the date and initial Revision Number Issue Date Date Inserted Inserted by initial Revision Number Issue Date Date Inserted Inserted by initial ...

Страница 6: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 RR 2 8 MAY 09 Blank Page ...

Страница 7: ...Bulletin Number Subject Manual Rev Number Manual Rev Date SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 SBL 1 8 MAY 09 SERVICE BULLETIN LIST ...

Страница 8: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 SBL 2 8 MAY 09 Blank Page ...

Страница 9: ...23 15 30 LEP 1 8 MAY 09 LIST OF EFFECTIVE PAGES An asterisk indicates pages changed added or deleted by the current revision F indicates a right foldout page with a blank back Section Page Date TITLE PAGE T 1 May 8 2009 INTRO INTRO 1 INTRO 3 to INTRO 6 May 8 2009 3 3 5 3 9 3 11 3 13 3 15 to 3 22 May 8 2009 ...

Страница 10: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 LEP 2 8 MAY 09 Blank Page ...

Страница 11: ...breviations INTRO 3 7 Safety Advisories INTRO 5 SYSTEM DESCRIPTION 1 Inmarsat System Overview 1 1 2 Equipment Overview 1 3 A HSD Xi 1 3 B ESCM 1 3 C SBB Services 1 3 1 SBB Packet Switched Services 1 3 2 SBB Circuit Switched Services 1 4 3 Primary and Secondary PDP Contexts 1 4 3 Equipment Specifications 1 4 4 Software Description 1 6 A Software Specifications 1 6 B Operational Software Part Number...

Страница 12: ...Initiated Self Test 1 10 SYSTEM OPERATION 1 Registering and Activating Terminals 2 1 A Preparing Terminal Information 2 1 1 Obtaining ISNs 2 1 2 Identifying the Swift64 Service Terminal Type 2 1 B Choosing Service Providers 2 2 C Registering Terminals 2 2 INSTALLATION 1 Advisories 3 1 2 Pre Installation Inspection 3 1 3 Mechanical Installation 3 1 4 Electrical Installation 3 2 A Cabling Notes 3 2 ...

Страница 13: ...SD X and HSD Xi Terminal Installation 4 1 2 Adjustment and Alignment Procedures 4 3 3 Modification History 4 3 MAINTENANCE AND REPAIR 1 Maintenance 5 1 A Basic Troubleshooting for the network mode HSD 5 1 B Connecting to the HSD Xi terminal through the network mode HSD Console Mode 5 2 C Loading Software to the HSD Xi Terminal 5 2 D Disconnecting Software Load Equipment 5 3 E Monitoring the HSD Xi...

Страница 14: ...rements 5 9 4 Return Materials Authorization RMA Procedure 5 9 3 Instructions for Continued Airworthiness 5 10 APPENDIX A INMARSAT SATELLITE BEAM COVERAGE A 1 APPENDIX B TROUBLESHOOTING CHECKLIST B 1 APPENDIX C INSTALLATION PLANNING CHECKLIST C 1 APPENDIX D INSTALLATION CHECKLIST D 1 APPENDIX E INMARSAT CAUSE CODES E 1 APPENDIX F SETTING UP SBB F 1 1 Requirements F 1 2 Configuring a Standard IP Pr...

Страница 15: ...m HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 2 of 4 3 17 Figure 3 9 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 3 of 4 3 19 Figure 3 10 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 4 of 4 3 21 Figure A 1 Satellite ORs A 1 Figure A 2 Inmarsat I3 Satellite Beam Coverage Composite Map A 2 Figure A 3 Inmarsat I...

Страница 16: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 TC 6 8 MAY 09 Blank Page ...

Страница 17: ...T OF TABLES Table 1 1 HSD Xi Characteristics and Specifications 1 5 Table 1 2 HSD Xi Terminal Environmental Characteristics 1 5 Table 1 3 Discrete Outputs 1 7 Table 1 4 Front Panel LEDs 1 8 Table 1 5 HSD Xi Maintenance Port Pin Description 1 9 Table 3 1 HSD Xi Input Output Strapping 3 5 Table E 1 Inmarsat Cause Code Definitions E 1 ...

Страница 18: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 TC 8 8 MAY 09 Blank Page ...

Страница 19: ... Inmarsat Cause Codes Appendix F Setting Up SBB NOTE An Illustrated Parts List is not included with this manual Only qualified avionics personnel knowledgeable in the technical and safety issues related to the installation of aircraft communications equipment should perform the installation procedures provided in this manual This manual includes general installation guidelines only it is not inten...

Страница 20: ...f satellite airtime services relating to the Product nor be responsible for any Product related airtime or network charges however incurred In the event EMS SATCOM is charged network or airtime fees relating to the customer s use of the Product the customer shall immediately upon notification by EMS SATCOM reimburse EMS SATCOM in full for such charges 5 Reference Documents Document Title EMS SATCO...

Страница 21: ...er to Noise DLNA Diplexer Low Noise Amplifier EIRP Effect Isotropic Radiated Power ESCM External Subscriber Configuration Module ESD Electrostatic Discharge EST Eastern Standard Time FAA Federal Aviation Authority FWD ID Forward ID GES Ground Earth Station GND Ground HGA High gain Antenna HPA High Power Amplifier Hz Hertz I O Input Output ICAO International Civil Aviation Organization IMN Inmarsat...

Страница 22: ...ber MSN Multiple Subscriber Number O I Outline and Installation Diagram OA Other Antenna ORR Ocean Region Registration ORT Owner Requirements Table PN Part Number POR Pacific Ocean Region POTS Plain Old Telephone System PPP Point to Point Protocol PPPoE Point to Point Protocol over Ethernet RAM Random Access Memory RF Radio Frequency RFU Radio Frequency Unit ROM Read only Memory RTN Return Rx Rece...

Страница 23: ...llation or maintenance tasks is familiar with and obeys standard aviation shop and safety practices The general safety advisories include the following WARNING SERVICE PERSONNEL MUST OBEY STANDARD SAFETY PRECAUTIONS SUCH AS WEARING SAFETY GLASSES TO PREVENT PERSONAL INJURY WHILE INSTALLING OR PERFORMING SERVICE ON THIS TERMINAL WARNING ASSOCIATED SATELLITE COMMUNICATIONS EQUIPMENT RADIATES HIGH FR...

Страница 24: ...AND OR CURRENT THE LOW ENERGY SOURCE THAT MOST COMMONLY DESTROYS ESDS DEVICES IS THE HUMAN BODY WHICH IN CONJUNCTION WITH NONCONDUCTIVE GARMENTS AND FLOOR COVERINGS GENERATES AND RETAINS STATIC ELECTRICITY TO ADEQUATELY PROTECT ESDS DEVICES THE DEVICE AND EVERYTHING THAT CONTACTS IT MUST BE BROUGHT TO GROUND POTENTIAL BY PROVIDING A CONDUCTIVE SURFACE AND DISCHARGE PATHS USE STANDARD INDUSTRY PREC...

Страница 25: ...ystem Overview The satellite communication system includes global satellite networks LESs and Mobile Earth Stations MESs The LES is the part of the satellite communication system that is on the ground These numerous international stations are responsible for routing voice and data calls from the MES to their destinations around the world The MES is the part of the satellite communication system th...

Страница 26: ...ocated over an Ocean Region OR the current OR names are Atlantic Ocean Region East AOR E Atlantic Ocean Region West AOR W Indian Ocean Region IOR Pacific Ocean Region POR These satellites provide worldwide telecommunication services for aviation shipping and land mobile terminal users The satellites connect to ground telecommunication systems through the LES GES The satellites that provide SBB ser...

Страница 27: ...cates with the channel card in the HSD Xi terminal The ESCM also contains a temperature control system and heating elements because the operating temperature range of the USM cards is smaller than the HSD Xi terminal When the temperature of the USIM cards is below their operational limit the ESCM turns on the heaters and holds the microprocessor chips in reset mode until the USIM cards reach their...

Страница 28: ...ces is based on the amount of time the connection is active 3 Primary and Secondary PDP Contexts A PDP context defines connection aspects such as routing QoS security and billing between the HSD Xi terminal and a core network SBB requires a primary PDP context to establish IP services Therefore it is activated first A primary PDP context is associated with a unique IP address A secondary PDP conte...

Страница 29: ...1559 9 MHz Output frequency range 1626 5 to 1660 5 MHz Receiver input impedance 50 ohms Transceiver output impedance 50 ohms Input level operational 107 dBm to 47 dBm Input level no damage 10 dBm External Interfaces Crosstalk bus ARINC 429 high speed 100 kbps data bus Maintenance port RS 232 data loader front and rear connector RS 232 serial bus supports 57 6 kbps data load capacity ISDN user inte...

Страница 30: ...onnector complies with ARINC 600 shell size 1 The top and middle connectors have 60 number 22 pins and the bottom connector has two number 16 pins one number 12 pin and two RF connections Loss of cooling Y Temperature B Humidity A Shock B Vibration SB Explosion Proofness E Water Proofness X Fluids Susceptibility X Sand and dust X Fungus Resistance F Salt Spray X Magnetic Effect Z Power Input A Vol...

Страница 31: ...of the Inmarsat Serial Number ISN The ISN consists of the type approval number and the Forward ID Each Forward ID is associated with Inmarsat Mobile Numbers that a user on the ground dials to reach the terminal on the aircraft There is a unique Inmarsat Mobile Number for each of the service types B Discrete Outputs The discrete outputs indicate the HSD Xi terminal status Table 1 3 Discrete Outputs...

Страница 32: ... indicate one of the following fault conditions Upon detection of a fault condition the red colored Fault LED is illuminated Channel card fault HPA fault Internal ROM fault Internal RAM fault Over temperature fault E HSD Xi Maintenance Port The HSD Xi maintenance port provides access to the HSD Xi maintenance utility which is a program that can monitor the HSD Xi and test HSD Xi functions The HSD ...

Страница 33: ...n 8 User Interfaces The HSD Xi terminal has the following user connections A Ethernet Data Interface The HSD Xi terminal has one 10BASE T Ethernet data interface B ISDN Interface The HSD Xi terminal has one ISDN bearer channel available through the ISDN interface C Maintenance Port Interface The HSD Xi terminal has one maintenance port located on the front panel of the terminal It provides remote ...

Страница 34: ...l training on the product It provides read only access to help users diagnose problems with the assistance of product support personnel 2 Field Representative Access Level 2 Password maint This level is for trained installers and product support personnel This access level supports read and limited write capabilities Users are able to disable mask clear faults change satellite or LES preferences v...

Страница 35: ...Forward ID When requesting ISNs please have the following information available End customer name including contact information Purchase order number Tail registration number aircraft type and serial number of the aircraft on which the terminal is being installed Serial number of the HSD and the HSD Xi terminal s Intended installation configuration mode Stand Alone or non Stand Alone EMS SATCOM Pr...

Страница 36: ...ng Terminals Contact your Inmarsat service provider and ask for a Registration for service activation of Aircraft Earth Station form Use the form to register for Swift64 services Complete the registration form for your HSD and your HSD Xi terminal You need the following information Customer information address and contact information Service provider details obtained from your ISP System and termi...

Страница 37: ...ent matches the model and part number ordered If components are missing from the shipment contact the supplier or EMS SATCOM Product Support immediately and report the problem Visually inspect the terminal for any shipping damage If any shipping damage has occurred contact the shipping carrier immediately and report the problem Check the HSD Xi terminal connectors for corrosion and damage If damag...

Страница 38: ...size 1 ARINC 600 connector size 1 coax contacts on HSD 440 tray installation specific size 5 coax contacts installation specific 4 Electrical Installation A Cabling Notes The system transmit loss between the network mode HSD terminal and the HSD Xi terminal should be as close as possible to 29 5 dB Figure 3 1 illustrates the System Transmit TX loss Figure 3 1 HSD Xi System Transmit TX Loss ...

Страница 39: ...plication pin TP5B 1 should be strapped and TP5A 0 should be left open C Maintenance Port Interface Use a HSD Xi maintenance port cable to connect directly to the front panel maintenance port of the HSD Xi The front connector maintenance port is a female micro D type M83513 04 B11N or equivalent connector You can also wire a permanent connector to the rear middle plug of the ARINC 600 connector fo...

Страница 40: ...igure 3 3 HSD Xi Remote Status LED Driver Circuits E System Mode Strapping To install the HSD 440 terminal in network mode strap these pins as follows TP 4A Strapped TP 4B Strapped TP 4C Strapped TP 4D Open NOTE Pins marked 0 are signaled by strapping to ICAO Common TP7K Pins marked 1 are signaled by an open circuit no connection ...

Страница 41: ...ector in the cabin area For the ISDN interface install an RJ 45 interface connector in the cabin area 5 Installing the HSD Xi and ESCM Install the HSD Xi and ESCM according to the System Interconnection diagrams Figure 3 7 Figure 3 8 Figure 3 9 and Figure 3 10 Figure 3 4 Figure 3 5 and Figure 3 6 provide outline drawings for the HSD Xi terminal and ESCM Mount the ESCM on a flat surface using four ...

Страница 42: ...rk mode follow these steps 1 Connect a computer to the maintenance port of the HSD terminal 2 Open a VT100 compatible terminal running an emulator program such as HyperTerminal ProComm Plus or similar and configure the serial port for ASCII 19200 bps 8 bits Parity None 1 Stop Bit No Flow Control 3 Log on to the HSD terminal using the password maint You can navigate through the HSD menus by pressin...

Страница 43: ...23 15 30 3 7 8 MAY 09 3 To access the classic AERO service parameter type 83 A prompt to enable or disable the classic channel card appears 4 Press 1 to enable the classic channel card 5 Press 0 to disable the classic channel card 6 To activate the new parameter setting reboot the network mode HSD terminal ...

Страница 44: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 8 8 MAY 09 Blank Page ...

Страница 45: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 9 8 MAY 09 Figure 3 4 HSD Xi Outline Diagram 1252 E 4124 Rev A00 Sheet 1 of 2 ...

Страница 46: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 10 8 MAY 09 ...

Страница 47: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 11 8 MAY 09 Figure 3 5 HSD Xi Outline Diagram 1252 E 4124 Rev A00 Sheet 2 of 2 ...

Страница 48: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 12 8 MAY 09 ...

Страница 49: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 13 8 MAY 09 Figure 3 6 ESCM Outline Diagram 1252 E 4123 Rev A00 ...

Страница 50: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 14 8 MAY 09 ...

Страница 51: ...ION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 15 8 MAY 09 Figure 3 7 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 1 of 4 ...

Страница 52: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 16 8 MAY 09 ...

Страница 53: ...ION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 17 8 MAY 09 Figure 3 8 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 2 of 4 ...

Страница 54: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 18 8 MAY 09 ...

Страница 55: ...ION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 19 8 MAY 09 Figure 3 9 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 3 of 4 ...

Страница 56: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 20 8 MAY 09 ...

Страница 57: ...ION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 21 8 MAY 09 Figure 3 10 System Interconnection Diagram HSD 440 Network Mode HSD Xi 1252 B 4303 Rev B00 Sheet 4 of 4 ...

Страница 58: ...Blank Page SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 3 22 8 MAY 09 ...

Страница 59: ...ollowing reasons To verify the operational readiness of the terminal during and after installation on an aircraft To verify that a fault exists and produce system reports for troubleshooting purposes To verify the operational readiness of repaired LRUs during re installation on an aircraft This section includes test and fault isolation procedures for the HSD X and HSD Xi terminals B Verifying the ...

Страница 60: ... HSD system recognizes the HSD Xi terminal press type 78 press ENTER and then press esc Report 78 is activated and displays information about the connected HSD Xi terminal To Verify that the Network mode HSD terminal is operating correctly 1 Connect a computer to the maintenance port utility of the network mode HSD terminal 2 To verify receive C No Rx signals press type 69 press ENTER and then pre...

Страница 61: ... HSD X and HSD Xi High speed Data Terminal 23 15 30 4 3 8 MAY 09 2 Adjustment and Alignment Procedures There are no adjustment or alignment procedures required for HSD Xi terminals 3 Modification History The HSD Xi terminal currently has no history of modifications ...

Страница 62: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 4 4 8 MAY 09 Blank Page ...

Страница 63: ...ng If the network mode HSD does not communicate with the aircraft avionics make sure that the multi control and BITE wiring is correct If you cannot make a Swift64 call with the HSD terminal activate report 38 and verify the power request value and verify that RF coax connections in the transmit path to the DLNA are properly installed If the network mode HSD drops calls when multiple calls are in ...

Страница 64: ...e port utility connects to the HSD Xi terminal 5 To access the HSD Xiterminal type the password maint Menu 1 of the HSD Xi maintenance port utility appears You are connected to the HSD Xi terminal C Loading Software to the HSD Xi Terminal You can perform a software upload on the HSD Xi terminal using the HSD Xi maintenance port or ARINC connector To upload HSD Xi terminal channel card software 1 C...

Страница 65: ... properly 1 Turn off the computer 2 Disconnect the serial cable connector from the COM port 3 Disconnect the cable connector from the HSD Maintenance Port E Monitoring the HSD Xi Terminal Monitor the HSD Xi terminal status by reading the maintenance port utility reports To activate a report 1 Connect to the maintenance port utility of the HSD Xi terminal 2 To view a list of reports press 3 To acce...

Страница 66: ...t you create a folder named HSD Load in the root directory and save the load program file and the software files to this folder 5 Apply power to the HSD Xi terminal 6 Close all other applications running on the computer The load program will not execute successfully if other programs are using the COM port 7 In the HSD Load folder double click ADT_LOAD exe The EMS Loader opens in a DOS window disp...

Страница 67: ...PR_9140_x_x_x RFControl hex 16 If no other software loads are required proceed to Verifying Software Loads on page 5 7 NOTE If the load fails restart the load from the beginning of the procedure If after two attempts the load still does not complete successfully contact EMS SATCOM Product Support for assistance 1 Loading Control Process Software This section describes how to load control processor...

Страница 68: ...tware loads are required go to Verifying Software Loads on page 5 7 NOTE If the load fails restart the load from the beginning of the procedure If after two attempts the load still does not complete successfully contact EMS SATCOM Product Support for assistance 2 Updating Displayed Software Versions Once you have uploaded the major software to the HSD Xi terminal you must load a BIN file to displa...

Страница 69: ...omplete successfully contact EMS SATCOM Product Support for assistance 3 Verifying Software Loads After loading all software as specified in the applicable software service bulletin released by EMS SATCOM verify that all software loaded successfully NOTE The screens shown in this procedure are examples only The software and other versions may differ from your terminal To verify software loads 1 Ap...

Страница 70: ...ir procedures must be completed by EMS SATCOM approved repair facilities A Repair Tools and Supplies No special supplies are required to repair this equipment HSD X and HSD Xi terminals that require service must be returned to EMS SATCOM or to an EMS SATCOM approved service center Refer to Test and Fault Isolation on page 4 1 for terminal testing requirements and procedures B Repair Procedures Thi...

Страница 71: ...l returned to EMS SATCOM must be returned in its original shipping container Failure to do so may invalidate the warranty If an HSD Xi terminal shipping container is unavailable the customer must request a replacement container from EMS SATCOM or assume responsibility for the packaging and shipping 4 Return Materials Authorization RMA Procedure If it is determined that a terminal must be returned ...

Страница 72: ...e HSD X and HSD Xi terminal Add the LRU part numbers and other necessary part numbers contained in this manual to the aircraft operator s appropriate aircraft illustrated parts catalog IPC Add all wiring diagram information contained in this manual to the aircraft operator s appropriate aircraft Wiring Diagram Manuals HSD X and HSD Xi terminals are considered on condition units No additional or ro...

Страница 73: ...uired by section 43 9 of the FAR The following scheduled maintenance tasks must be added to the aircraft operator s appropriate aircraft maintenance program Recommended periodic scheduled servicing tasks None required Recommended periodic inspections None required Recommended periodic scheduled preventative maintenance tests tests to determine system condition and or latent failures None required ...

Страница 74: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 5 12 8 MAY 09 Blank Page ...

Страница 75: ...n East AOR E Atlantic Ocean Region West AOR W Indian Ocean Region IOR Pacific Ocean Region POR Figure A 1 represents the satellite ORs with approximate transfer coordinates for satellite transitions Figure A 1 Satellite ORs The four satellite ORs are made up of smaller spot beam coverage areas The following maps show the Inmarsat satellite spot beam coverage for the four ORs and a composite map of...

Страница 76: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 A 2 8 MAY 09 Figure A 2 Inmarsat I3 Satellite Beam Coverage Composite Map ...

Страница 77: ...HSD Xi High speed Data Terminal 23 15 30 A 3 8 MAY 09 Figure A 3 Inmarsat I 3 Satellite Beam Coverage OR Maps At the time of publishing three I 4 satellites provide SBB services Americas 98W EMEA 25E and Asia Pacific 143 5E Figure A 4 shows the area covered by I 4 satellites ...

Страница 78: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 A 4 8 MAY 09 Figure A 4 I 4 Satellite Coverage Map ...

Страница 79: ...ys to be incorporated into the system databases at the LES level New terminals being commissioned are not validated by the LES until their customer database has been updated by Inmarsat to reflect the registration and activation of your terminal NOTE To verify that the service registration information has been validated at the LES call 33 POUND KEY for assistance Confirm with the LES operator that...

Страница 80: ...w devices or systems connected to the terminal Have any connecting devices or equipment been removed or replaced If so check that all new or replaced connections are attached and configured correctly Have you changed service providers or re configured the system in any way 6 Are your Primary and Secondary LES Access Codes programmed for all ORs The system default for LES access codes is set to 0 z...

Страница 81: ...1 2 3 4 Contact your Service Provider and provide the four 12 digit ISNs from above IMSI Number 1 IMSI Number 2 Record the FWD IDs received from your Service Provider or from Inmarsat and corresponding Inmarsat Mobile Numbers IMN 1 2 3 4 FWD IDs last 6 digits of ISN IMNs ISDN speech ISDN 3 1 kHz audio ISDN 56 kbps ISDN 64 kbps ISDN 4 8k audio MPDS Service Provider LES Access Codes depend on Servic...

Страница 82: ...a Multi Control BITE A B HPA Mute A B Power ISDN Wire the ISDN line Channels 1 and 2 operate over ISDN 1 ISDN 1 Ethernet Wire the Ethernet port for SBB Ethernet 1 Inertial Navigation System INS Analog Tip Ring POTS CEPT E1 Future PBX applications optional 4 Configuration Program the Land Earth Station LES Access Codes Configure the CNX Cabin Gateway if required Installation Planning Steps ...

Страница 83: ...Checks completed by Approved Witnessed by Section Parameter Item N A 9 Value Installation Mechanical Physical Service maintenance access Environmental considerations see HSD Xi Terminal Environmental Characteristics on page 1 5 Fan Tray Plug configuration see Chassis bonding see Fan rotation unobstructed ARINC 600 Con Polarized pins Installation Electrical Power Connections 28 V dc polarity 115 V ...

Страница 84: ...ired to RJ45 distribution points Remotes Manual reset switch operation Maintenance port DB9 access Power and Fault indicators RF Coaxial Rx i p cable loss Tx o p cable loss Antenna Antenna manufacturer and type Wired as per manufacturer Configuration LES Access codes Stand Alone Mode FWD ID Test System Power Up Visual LED indications Power up computer display Test On Air System Logon Reset message...

Страница 85: ... Azimuth HSD Xi terminal CH 1 Signal 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 360 SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 D 3 8 MAY 09 ...

Страница 86: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 D 4 8 MAY 09 Blank Page ...

Страница 87: ...4 Call cleared MES initiated preemption 1145 Attempted call cleared pre empted at MES 1146 Attempted call abandoned by MES terminal 1202 Handover MES ready 1281 Call failed MES cannot accept 1291 Call failed MES cannot accept at present 1351 Call cleared insufficient free memory 1361 Call cleared by MES cable unwrap 1362 Call cleared long interruption in reception at MES 1363 MES secondary clear d...

Страница 88: ...d preemption failed no channel available 1856 Call rejected spot beam selection failed 1857 Handover failed channel not available 2000 MES int reject MES RQ invalid CNO 2001 MES int reject MES RQ failed qualification 2010 MES int reject MES RP invalid CNO 2011 MES int reject MES RP failed qualification 2012 MES int reject MES RP operation timeout 2020 MES int reject NCSA missing 2021 MES int rejec...

Страница 89: ...lone Mode finished seeking network 2080 SIM error check SIM is inserted correctly 2090 MES int reject ORR query invalid 2091 MES int reject ORR invalid 2092 MES int reject MES RR failed qualification 2093 MES int reject MES RR invalid CNO 2094 MES int reject NCRA missing 2095 MES int reject NCRA lost lock 2100 MES int reject illegal call type 2101 MES Int reject illegal peripheral 2102 Call reques...

Страница 90: ...und Primary Standalone 8023 ACSE Found Secondary Standalone 8024 ACSE found primary NGNCS 8025 ACSE found secondary NGNCS 8030 ACSE NSR Invalid 8040 ACSE Inert 8041 ACSE ODU Status 8080 ACSE NSR Valid 8081 ACSE NSR Valid LES A 8100 ACSE Booting 8110 ACSE Booted 8120 ACSE FIDR ID Invalid 8200 ACSE Spot Beam Selection 8201 ACSE Next Spot Beam 8202 ACSE Successful Spot Beam Selection 8203 ACSE Failed...

Страница 91: ...n 8483 ACSE Fixed Authentication End 8484 ACSE Fixed Power Control 8485 ACSE Fixed MES Connect 8486 ACSE Fixed Ringing Begin 8500 ACSE Mobile Begin 8501 ACSE Mobile MES RQ1 8502 ACSE Mobile MES RQ2 8503 ACSE Mobile Call Type Set 8510 ACSE Mobile Tune NCSA 8511 ACSE Mobile Channel Assignment 8520 ACSE Mobile Clearing Call 8521 ACSE Mobile Selective Clear 8580 ACSE Mobile SCPC Begin 8581 ACSE Mobile...

Страница 92: ... 9086 ACSE ext sounder turned on 9087 ACSE ext sounder turned off 9088 ACSE timer about to expire 9090 ACSE Smartcard activated 9091 ACSE Smartcard removed 9092 ACSE Smartcard error 9100 Peripheral on hook 9101 Peripheral off hook 9102 Peripheral connected 9103 Peripheral ringing 9104 Peripheral ready 9105 Peripheral hanging up 9106 Peripheral hang up 9107 Peripheral not responding 9108 Peripheral...

Страница 93: ...CT SP good 400002 CT SP full 400003 CT SP access denied 400080 CT SP find 400081 CT SP enumerate 400082 CT SP no entries 400090 CT SP delete 400100 CT SP spot beam selection 400105 CT SP MPDS 400110 CT SP ocean region registration 400111 CT SP ORR query 400112 CT SP log off 400120 CT SP cable call 400200 CT SP go idle 400201 CT SP go idle due to configuration 400202 CT SP selective clear 400208 CT...

Страница 94: ...s 11D4 Call cleared credit card data information invalid 11D5 Call cleared invalid country code 11D6 Call cleared PID information is not consistent 11D7 Call rejected invalid service for Pri 1 or 2 call 11D8 Call cleared dialed number not 2 or 3 digits for Pr 1 or 2 call 11E0 Call cleared invalid credit card PIN at this LES 11E1 Call cleared too many invalid credit card call attempts 12B1 Call cle...

Страница 95: ...ing vector 15C4 Call failed no service address and no scrambling vector 15C5 Call cleared incomplete credit card data information 15C7 Call failed LES time out no MES Connect 15C9 Call cleared no authentication reply 15CA Call cleared notification ack not received 15CB Call cleared invalid sequence number in notification ack 15CC Handover failed no response to request 15CD Handover failed MES not ...

Страница 96: ...0A0 CT SP any 4000F0 CT Terminal ID 4000F1 CT Options 4000F2 CT config names 80010F Mobile 64k speech 8D0FFF Mobile Mini M 8E0FFF Mobile HSD 8F0FFF Mobile 90A0 EXPPORT bonding started 90A1 EXPPORT bonding ended 90A2 EXPPORT remote panel present 90A3 EXPPORT remote panel removed 90B0 ACSE MPDS mode selected 90B1 ACSE SCPC mode selected 90C0 ACSE transmit on 90C1 ACSE transmit off 90D0 ACSE spot bea...

Страница 97: ...201 RF error RX VHF B202 RF error RX Lband B204 RF error RX VHF B208 RF error TX Lband B210 RF error RF error B220 RF error Ref error B27F Mod watchdog tripped B280 Generic voice codec errors B281 TMS spurious interrupt B300 Outdoor terminal failure check connections to ODU B301 ODU error cannot set cable attenuator B310 ODU error power response missing B311 ODU error tune response missing B312 OD...

Страница 98: ... and try again B500 Battery charging communication failure B501 Power supply error B580 Battery is over temperature charging disabled B581 Battery temperature is now ok charging enabled C00103 Fixed AMBE C0010F Fixed 64k speech C00124 Fixed aero 64k speech C00404 Fixed data C00504 Fixed facsimile C00606 Fixed 64k UDI C00607 Fixed 56k UDI C00610 Fixed 64k audio 3k1 C00622 Fixed aero 64k UDI C00623 ...

Страница 99: ... straight through cable 2 Configuring a Standard IP Primary PDP Context The connection that you configure in this section defines the primary PDP context You can configure any type of connection for the primary PDP context but a standard IP connection as illustrated in this procedure is the most common and useful To create other connections see Creating Connections for Other Services on page F 7 N...

Страница 100: ... Create a new connection The New Connection Wizard appears as shown in Figure F 2 Figure F 2 New Connection Wizard 4 Click Next The Network Connection Type page appears as shown in Figure F 3 Figure F 3 Network Connection Type Page 5 Click Connect to the Internet and then click Next The Getting Ready page appears as shown in Figure F 4 ...

Страница 101: ...F 4 Getting Ready Page 6 Click Set up my connection manually and then click Next The Internet Connection page appears as shown in Figure F 5 Figure F 5 Internet Connection Page 7 Click Connect using a broadband connection that requires a user name and password and then click Next The Connection Name page appears as shown in Figure F 6 ...

Страница 102: ... ISP Name box type BGAN and then click Next The name you type is the name that appears in the list of connections available on your computer The Connection Availability page appears as shown in Figure F 7 Figure F 7 Connection Availability Page 9 Click Anyone s use or My use only and then click Next The Internet Account Information page appears as shown in Figure F 8 ...

Страница 103: ...ype a user name that you will remember 11 In the Password box type a password that you will remember 12 In the Confirm password box retype your password 13 Click Next The Completing the New Connection Wizard page appears as shown in Figure F 9 Figure F 9 Completing the New Connection Wizard Page 14 To complete the connection setup click Finish The Connect dialog box appears as shown in Figure F 10...

Страница 104: ...15 30 F 6 8 MAY 09 Figure F 10 Connect Dialog Box 15 Click Properties The Properties dialog box appears as shown in Figure F 11 Figure F 11 Properties Dialog Box 16 In the Service Name box type the service string SBB BACKGROUND USER username PASS password APN my apn com SBB BACKGROUND for Background IP service ...

Страница 105: ...xt as a background SBB connection NOTE Some routers do not support dial strings To access a service configure the default service name in the data I O card and the HSD X and HSD Xi terminal will add the service name to the call 3 Creating Connections for Other Services You can create a connection for every service you use on your computer such as 32 kbps and 64 kbps services To create a connection...

Страница 106: ...SYSTEM DESCRIPTION INSTALLATION AND MAINTENANCE MANUAL eNfusion HSD X and HSD Xi High speed Data Terminal 23 15 30 F 8 8 MAY 09 Blank Page ...

Отзывы: