SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
23-15-30
3-5
8 MAY 09
F.
HSD-Xi Input/Output Strapping
Table 3-1 provides the Input/Output (I/O) strapping for the HSD-Xi.
Table 3-1 HSD-Xi Input/Output Strapping
MP11A
MP11B
MP11C
Input/Output Configuration
1
1
1
Invalid
1
1
0
Restricted (disable Data I/O)
1
0
1
MPDS (Future)1
1
0
0
SCPC (M4) only
0
1
1
Unrestricted (recommended if
there are no specific user
requirements)
0
1
0
Not Assigned
0
0
1
Not Assigned
0
0
0
Reserved
NOTE: MP11D: Reserved, 0 = FWD Address Comm
G. User Interfaces
For the HSD-Xi terminal Ethernet interface, install an RJ-45 interface connector in the
cabin area. For the ISDN interface, install an RJ-45 interface connector in the cabin area.
5.
Installing the HSD-Xi and ESCM
Install the HSD-Xi and ESCM according to the System Interconnection diagrams,
Figure 3-7, Figure 3-8, Figure 3-9, and Figure 3-10.
Figure 3-4, Figure 3-5, and Figure 3-6 provide outline drawings for the HSD-Xi terminal
and ESCM. Mount the ESCM on a flat surface using four screws or bolts that fit the 0.125
inch holes in the mounting flange. You can install the ESCM a maximum of three meters
away from the HSD-Xi terminal.
A. Hardware and Software Requirements
You need a HSD-Xi terminal, 1252-A-4100, and an ESCM, 1252-A-4120, to use SBB
services.
You need the following software to use SBB services.
•
HSD-Xi, LI-1252-42001
•
HSD-440, LI-1252-33374
B. User Interfaces
You can access SBB services through the following interfaces:
•
Ethernet
•
ISDN