SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-X and HSD-Xi High-speed Data Terminal
23-15-30
3-1
8 MAY 09
INSTALLATION
This section describes how to install HSD-Xi on an network mode HSD terminal. It includes
the following sections:
•
•
•
•
•
Installing the HSD-Xi and ESCM
•
1.
Advisories
Before performing any installation procedures, read the safety advisories listed in the
Introduction on page INTRO–5 of this manual.
2.
Pre-Installation Inspection
Before installing a HSD-Xi terminal, conduct a pre-installation inspection of all parts to make
sure that no damage occurred during shipping:
•
Unpack the HSD-Xi terminal from the shipping container(s).
•
Verify that the part number displayed on the shipping box and equipment component
matches the model and part number ordered. If components are missing from the
shipment, contact the supplier or EMS SATCOM Product Support immediately and report
the problem.
•
Visually inspect the terminal for any shipping damage. If any shipping damage has
occurred, contact the shipping carrier immediately and report the problem.
•
Check the HSD-Xi terminal connectors for corrosion and damage. If damage is noted, do
not apply power to the terminal. Contact the supplier or EMS SATCOM Product Support
immediately to report the problem.
3.
Mechanical Installation
This section describes the mechanical installation requirements for the HSD-Xi. The System
Interconnection diagrams are provided at the end of this section. Figure 3-7 to Figure 3-10
provide connection details for the HSD-Xi terminal. All foldout pages are odd-numbered and
not-backed for print production purposes.
Electronic Cable Specialists (ECS) supplies a 2-MCU ARINC 600 mounting tray, part number
200-910002-101, for installing the HSD-Xi terminal. You can contact ECS at
www.ecsdirect.com.