A standard VT100 compatible terminal or computer running an emulator
program such as HyperTerminal©, ProComm (PCPLUS)©, or another serial
communication package provides the user interface to the HSD-Xi terminals
MPU. Configure the connection as follows:
•
Bits per second—19200
•
Data bits—8
•
Parity—none
•
Stop bits—1
•
Flow control—none
The HSD-Xi terminals supports two different end user access levels within the
maintenance port architecture: End User and Field Representative.
(1) End User Access: Level 1
Password:
menu
This limited-access level is for anyone without technical training on the product. It
provides read-only access to help users diagnose problems with the assistance of
product support personnel.
(2) Field Representative Access: Level 2
Password:
maint
This level is for trained installers and product support personnel. This access level
supports read and limited write capabilities. Users are able to disable/mask/clear
faults, change satellite or LES preferences, view and modify certain EEPROM
parameters, and perform other maintenance or upgrade functions.
"Test and Fault Isolation" on page 4-1 provides a detailed description of the two levels
of user access and the menus, report selections, functions, and system diagnostic
procedures of the HSD-Xi terminals MPU.
9.
Initiated Self-Test
The initiated self-test occurs during the power up sequence, or when you press and hold down
the TEST button on the front panel of the terminal for 100 milliseconds or more.