2.1
Battery Markings
Battery Type
Secondary (rechargeable) Li or Li-ion
Cell Designation
IFpP/34/201/173/M/-10+40/90
Module Designation
IFpP34/201/173[8S]M/-10+40/90
Battery System Designation
IFpP34/201/173[48S]M/-10+40/90
System Capacity
100Ah
Nominal Voltage
153.6V
Watt-hour
15.36kWh
Caution Statement
WARNING! A battery can present a risk of electrical shock,
fire, or explosion from vented gases. Observe proper
precautions.
Disposal
Electronic Device: Do not throw away
Proper disposal of batteries is required. Refer
to your local codes for disposal requirements.
Recommended Charge
instructions
Charging is only allowed using the provided Elektrobank 14
system, do not try charging with a different charger
3
External RCD Requirements
This product requires an external RCD Type A, 30mA to be installed on every
subcircuit powered by the backup port