7.1.2
Mount unit on wall bracket
6.
Using a two-man lift, place the Elektrobank 14 onto the wall bracket.
7.
Fix the small top fixing bracket with the 2x supplied M6 bolts
Figure 4 - Top Fixing Bracket
7.2
Floor Mount
1.
Floor Mounting is suitable when the wall is considered not completely structurally sound to
mount the unit, this could be the case for many types of wooden structures or walls with
plastic/wooden cladding.
2.
Floor Mounting is only viable when there is a suitable vertical structural member or wall to fix
the top of the unit to. The unit cannot be mounted freestanding.
3.
Floor mounting can only take place on a flat concrete base. A separate risk assessment shall be
carried out to ensure the platform is structurally sound to mount the unit to.
4.
Fit the base unit to the unit using the provided M6 bolts and washers.
5.
Place the unit next to the wall with the wall bracket and mark the height that the wall bracket
should be fitted at to still provide support to stop the unit from toppling forwards.
6.
Fit the wall bracket ensuring level
7.
Lift the unit onto the wall bracket and adjust the feet until the feet begin to take the weight of
the unit
8.
Fix the small top fixing bracket with the 2x supplied M6 bolts as per Figure 4 - Top Fixing Bracket