IMPORTANT SAFETY INFORMATION

THIS IS A HEATING APPLIANCE

DANGER

: Indicates a hazardous situation which, if not avoided, will 

result in death or serious injury. 

WARNING

: Indicates a hazardous situation which, if not avoided, 

could result in death or serious injury.

CAUTION

: Indicates a hazardous situation which, if not avoided, 

could result in minor or moderate injury.

NOTICE

: Addresses practices not related to personal injury.

• 

An unvented room heater having an input rating of more than 

6,000 Btu per hour shall not be installed in a bathroom

• 

An unvented room heater having an input rating of more than 10,000 

Btu per hour shall not be installed in a bedroom or bathroom.

• 

Due to high temperatures, the appliance should be located out of 

traffic and away from furniture and draperies.

• 

Children and adults should be alerted to the hazard of high surface 

temperature and should stay away to avoid burns or clothing 

ignition.

• 

Young children should be carefully supervised when they are in 

the same room with the appliance.

• 

Do not place clothing or other flammable material on or near the 

appliance.

•  Avoid the use of scented air fresheners (plug in type air 

fresheners, etc. ) while the log set is in operation. Air fresheners 

produce a residue in the air similar to candles and may produce 

a soot like substance.

• 

Avoid the use of scented or decorative candles while the log 

set is in operation. Candles produce a residue in the air that 

creates a soot like substance. Burning candles while the log 

set is operating magnifies the problem. It should be noted that 

candles, in general, produce soot. The amount of time burned 

and the quantity of candles burned will determine the amount 

of soot produced and deposited.

• 

Installation and repair should be done by a QUALIFIED SERVICE 

PERSON. This appliance should be inspected before use and at 

least annually by a professional service person. More frequent 

cleaning may be required due to excessive lint from carpeting, 

bedding materials, etc. It is imperative that control compartments, 

burners and circulating air passageways of the appliance be 

kept clean.

• 

DO NOT use this room heater if any part has been under water. 

Immediately call a qualified service technician to inspect the 

room heater and to replace any part of the control system and 

any gas control which has been under water.

• 

You must operate heater with fireplace screen in place. 

• 

Do not place trash, logs or other articles on the log set during 

operation.

•  During manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, films 

or bonding agents. These bonding agents are not harmful but 

may produce annoying smoke and smells as they are burned 

off during initial operation of the appliance. This is a normal 

temporary occurrence. A window should be opened during the 

initial bake out period. 

• 

Correct installation of the ceramic fiber logs, proper location of 

the heater and annual cleaning are necessary to avoid potential 

problems with sooting. Sooting, resulting from improper 

installation or operation, can settle on surfaces outside the 

fireplace. See instructions for proper installation.

• 

WARNING: Do not allow fans to blow directly into the 

fireplace. Avoid any drafts that alter burner flame patterns.

• 

WARNING: Do not use a blower insert, heat exchanger insert 

or other accessory not approved for use with this heater.

• 

WARNING! This fireplace needs fresh air for ventilation to 

run  properly.  This  fireplace  has  an  ODS  (oxygen  depletion 

sensor) which will shut down the heater if adequate fresh air is 

not available. See troubleshooting section in the instructions.

• 

WARNING: DO NOT operate this appliance unless all 

components including logs, burners, and controls are in good 

working condition. Never operate this appliance if any log or 

twig is broken, or out of their intended position. Refer to the 

Log set placement instructions for correct log and twig 

positioning.   

Replacement components are available through your local 

dealer as indicated in the How to Order Repair Parts section of 

the appliance manual.

• 

Keep appliance area clear and free from combustible materials, 

gasoline and other flammable vapors and liquids.

• 

WARNING: Failure to keep the primary air opening(s) of the 

burner(s) clean may result in sooting and property damage.

WARNING

When used without adequate combustion and ventilation air, 

heater may give off CARBON MONOXIDE, an odorless, poison-

ous gas. 

Do not install heater until all necessary provisions are 

made for combustion and ventilation air. Consult the writ-

ten instructions provided with the heater for information 

concerning combustion and ventilation air. In the absence 

of instructions, refer to the National Fuel Gas Code, ANSI 

Z223.1/NFPA 54, Air for Combustion and Ventilation, or 

applicable local codes. 

This heater is equipped with a PILOT LIGHT SAFETY SYS-

TEM designed to turn off the heater if not enough fresh air 

is available.

DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!

If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and 

control compartment clean. 

CARBON MONOXIDE POISONING MAY LEAD TO DEATH.

Early signs of carbon monoxide poisoning resemble the flu, 

with headache, dizziness and/or nausea. If you have these 

signs, heater may not be working properly. Get fresh air at 

once! Have heater serviced. 
Some people — pregnant women, persons with heart or lung 

disease, anemia, those under the influence of alcohol , those 

at high altitudes — are more affected by carbon monoxide 

than others.
The pilot light safety system senses the depletion of oxygen 

at its location. If this heater is installed in a structure having a 

high vertical dimension, the possibility exists that the oxygen 

supply at the higher levels will be less than that at the heater. 

In this type of application, a fan to circulate the structure air will 

minimize this effect. The use of this fan will also improve the 

comfort level in the structure. When a fan is used to circulate 

air, it should be located so that the air flow is not directed at 

the burner.

Содержание VFD26FM Series

Страница 1: ... do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup plier Installer Leave this manual with the appliance Consumer Retain this manual for future reference ...

Страница 2: ...8 10 000 BTU MILLIVOLT LIGHTING INSTRUCTIONS 19 MILLIVOLT LIGHTING INSTRUCTIONS 20 INTERMITTENT PILOT LIGHTING INSTRUCTIONS 21 HYDRAULIC THERMOSTAT LIGHTING INSTRUCTIONS 22 PILOT FLAME CHARACTERISTICS 23 24 MAIN BURNER AND THERMOSTAT OPERATION 25 MILLIVOLT WIRING 26 MILLIVOLT TROUBLESHOOTING 27 IP ELECTRONIC SYSTEM OPERATING INSTRUCTIONS 28 IP ELECTRONIC SYSTEM WIRING DIAGRAM 29 INTERMITTENT CONTR...

Страница 3: ...g are necessary to avoid potential problems with sooting Sooting resulting from improper installation or operation can settle on surfaces outside the fireplace See instructions for proper installation WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns WARNING Donotuseablowerinsert heatexchangerinsert or other accessory not approved for u...

Страница 4: ...f this occurs some new internal rusting could occur If the valve is left open then treat the container as a new tank Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty NO ODOR DETECTED ODOR FADE Somepeoplecannotsmellwell Somepeoplecannotsmell the odor of the chemical put into t...

Страница 5: ...lt in sooting and property damage Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with unvented room heater 3 Installer should show owner how to start and operate unvented room heater Always consult your local Building Department regarding regula tions codes or ordinances which ap...

Страница 6: ... shown in Figure 2 for corner rough opening Be sure to provide gas line for fireplace and electrical power for optional blower assembly 1 Attach two nailing flanges to firebox sides with two 10 x 1 2 screws for each nailing flange 2 Gas line connections must be made at this time When facing the appliance the gas supply will enter on the right hand side See Gas Supply page 11 3 Insert fireplace int...

Страница 7: ...INE OPENING JUNCTION BOX ASSEMBLY GAS LINE OPENING J I K B C G A D E Figure 4 VFD26 Series Dimensions Index Letter Dimension A 30 1 4 768mm B 30 762mm C 13 1 8 333mm D 18 1 8 460mm E 26 660mm G 25 635mm I 36 1 4 921mm J 36 1 4 921mm K 51 1 4 1302mm ...

Страница 8: ...ermostat FREC Electric Remote Control FWS 1 Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Wireless Remote Wall Thermostat Water vapor is a by product of gas combustion An unvented room heater produces approximately one ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather than a primary heat source...

Страница 9: ... are confined spaces Furnaces installed in a confined space which supply heated air to areas outside the space must draw return air from outside the space through tightly sealed return air ducts A confined space must have 2 openings into the space for combus tion air One opening must be within 12 inches of the ceiling and the other must be within 12 inches of the floor The required sizing of these...

Страница 10: ...eiling and one with 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces In most cases for direct communication with the outdoors or direct communication through a vertical duct a free area opening of one square inch per 4 000 BTU HR of heater input rating for each grill If a horizontal duct is used a grill free ar...

Страница 11: ...l Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flex ible appliance connector cannot exceed three feet in length Pressure Testing of the Gas Supply System 1 To check the inlet pressure to the gas valve a 1 8 3mm N P T plugged tapping accessible for test gauge connection must be placed immediately upstream...

Страница 12: ...m the top of the fireplace opening to the ceiling should not be less than 36 inches Mantel Clearances for Built in Installation Figure 9 Do not attach combustible material to the mantel of your fireplace This is a fire hazard HEAT FLOW Figure 10 No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace This is a heating appliance The flow of heat can...

Страница 13: ...5 Remove shrink wrap and logs from fireplace 6 Place back base and fireplace in desired location 7 Connect gas line and electrical wiring at this time in accor dance with local codes ELECTRICAL CONNECTION OPENING GAS LINE CONNECTION OPENING 8 Place mantel assembly around fireplace and center Replace the screw removed in step 3 to secure fireplace to mantel assembly 30816 7 0814 Page 13 INSTALLATIO...

Страница 14: ...logs per the Log Placement Instructions See Page 16 14 Install hood See Page 15 9 Attach mantel assembly to studs in the wall through the back brace using two 3 drywall screws provided 10 Slide front base under front of mantel assembly 30816 7 0814 Page 14 INSTALLATION OF FIREPLACE AND MANTEL ...

Страница 15: ...w holes in fireplace Attach top frame to fireplace Use two 8 x 1 2 Phillips screws for top frame 5 Replace bottom louver 6 Replace top louver 3 PIECE FRAME KIT SIDE TRIM HOOD INSTRUCTIONS 1 Remove upper louver grasp louver at left and right ends lift and pull forward 2 Remove screen frame assembly 3 Outer trim must be installed before installing hood 4 Place the top hood flange on top of the fireb...

Страница 16: ...This step is optional for VFD26FP3L10 log sets Place front twig 5 onto 1 log and flat area on 3 log The bottom of the front twig is to be placed behind the grate tang that is second from the left Attention Do not use Figures 12 and 13 to order logs Refer to Pages 34 to 35 Parts list and Page 36 Parts View to order logs Refer to Figure 12 for the following warning CAUTION Failure to position the pa...

Страница 17: ...between the front and middle logs Rock wool should not be placed in the area of the pilot assembly Glowing embers rock wool can cover the burner in between the front and middle logs but very little is necessary to cover this area Excess ember material causes the yellow flame to become orange and stringy Apply just enough to obtain slow glow and a gold yellow flame Replacement of loose material glo...

Страница 18: ...or location of items discussed below Do not use cleaning fluid to clean logs or any part of heater Logs brush with soft bristle brush or vacuum with brush attachment Remove loose particles and dust from the burner areas controls piezo covers and grate Inspect and clean burner air intake hole Remove lint or particles with brush Failure to keep air intake hole clean will result in sooting and poor c...

Страница 19: ...ttom louver assembly if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Fol low B ...

Страница 20: ...if applicable 3 Set REMOTE OFF ON switch to OFF 4 Turn off all electric power to the appliance if applicable 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait ten minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety informat...

Страница 21: ...OR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which can be lighted with the manual on off switch a remote control or by switching the receiver switch to the ON position When lighting the pilot follow these instructions exactly B Before li...

Страница 22: ...PLIANCE 1 Set thermostat gas control knob to lowest setting 2 Turn off all electric power to appliance if service is to be performed if applicable LIGHTING INSTRUCTIONS 7 Turn gas control knob counterclockwise to PILOT 8 Push in gas control knob all the way and hold in Repeat edly push the piezo ignitor button until pilot is lit or use a match to light pilot Continue to hold the control knob in fo...

Страница 23: ...he incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down MILLIVOLT PILOT Correct Pilot Flame Pattern Figure 15 Incorrect Pilot Flame Pattern Figure 16 If pilot flame pattern is incorrect as shown in Figure 16 See Troubleshooting page 26 HYDRAULIC THERMOSTAT PILOT Correct Pilot Flame Pattern Figure 17 In...

Страница 24: ...the Oxygen Depletion Sensor as follows 1 Clean the ODS pilot by loosening nut B from the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air pressure through the holes indicated by the arrows This will blow out foreign materials such as dust lint and spider webs Tighten nut B also by grasping nut A A B Millivolt Pilot Figure 21 B A Hydraulic Thermostat Pilot...

Страница 25: ...5 setting Cleaning and Maintenance Main Burner WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding materials etc Logs B...

Страница 26: ...burner assembly NOTICE Do not let remote control receiver come in contact with burner assembly On circulating vent free firebox install remote control receiver behind bottom louver Refer to remote control installation and operating instructions for more details on remote control MILLIVOLT WIRING REMOTE OFF ON SWITCH A DISTANCE FERME OUVERT INTERRUPTEUR IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH ...

Страница 27: ... f Gas regulator setting is not correct Replace gas regula tor 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loos...

Страница 28: ...rating season or in power outage periods it is recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as shown in Figure 25 Refer to page 11 for gas pressure requirements Note The gas control has a manual HI LO flame adjustment knob regulator that allo...

Страница 29: ...ION Do not operate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier GND PILO...

Страница 30: ...fore proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections between the wire harnesses and system components are proper and positive Verify that the static inlet pressure meets the m...

Страница 31: ...wire harness 4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow adjuster screw is not sealed Check if pilot flow adjust screw is set correctly in accordance with the appliance manufacturer instructions If necessary correct it 3 Replace pilot tube or ...

Страница 32: ...e and verify voltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at the outlet pressure test point out according to the manufacturer s instruction If not in accordance replace the gas valve 1 Verify the electrical connections integrity and make sure they are in accor...

Страница 33: ...CODE ANSI NFPA 70 LAT EST EDITION A factory installed junction box is located on the lower right side of the fireplace Wiring must be fed to the junction box and attached to the receptacle that is provided Leave approximately 6 of wire in the junction box for connection Attach black wire to hot side brass screws of the receptacle and white wire to opposite side silver screws of receptacle The grou...

Страница 34: ... REGULATOR LPG 29 R2708 IGNITOR PIEZO VFD26F M P 30L N P 10 R3623 PILOT ASSEMBLY LPG 10 R3624 PILOT ASSEMBLY NAT 11 21590 PILOT BRACKET LPG 11 23106 PILOT BRACKET NAT 12 23449 PILOT SHIELD 14 R9022 BURNER TUBE 16 P182 ORIFICE LPG 16 P288 ORIFICE NAT 18 23473 BURNER BASE PLATE ASSEMBLY 20 R2423 CONNECTOR MALE 21 R3625 VALVE LPG 21 R3626 VALVE NAT 22 23493 TUBING ASSEMBLY SUPPLY 23 23496 TUBING ASSE...

Страница 35: ...FLEX WITH SHUT OFF VFD26F M P 70L10 N P 10 R11327 PILOT ASSEMBLY LPG 10 R11328 PILOT ASSEMBLY NAT 11 30703 PILOT BRACKET LPG 14 27426 BURNER TUBE 16 P214 ORIFICE NAT 16 P193 ORIFICE LPG 18 30704 BURNER BASE PLATE ASSEMBLY 20 R6207 ELBOW NPT x TUBE 21 R11210 VALVE NAT 21 R11211 VALVE LPG 22 30981 TUBING ASSEMBLY INLET 23 33808 TUBING ASSEMBLY LPG 23 33807 TUBING ASSEMBLY PILOT NAT 24 R7063 REGULATO...

Страница 36: ...EMBL INTERMITTENT PILOT VALVE A Y SSEMBL VFD26F M P 2 3 VFD26F M P 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 22 20 21 18 23 24 25 26 30 41 42 43 44 45 1 1 1 THERMOSTATIC VALVE Y ASSEMBL 22 20 21 23 27 28 29 26 29 37 39 36 35 30 38 32 33 34 26 11 10 21 31 20 23 25 24 23 22 19 ...

Страница 37: ...e The magnets on the bottom of speed control will sufficiently hold the speed control in place 13 Attach fan control bracket to upper right side of firebox with one 10 x 1 2 hex screw provided See Figure 27 14 Attach wire harness from the FBBX kit to the terminals on the fan control 15 Route the wire harness along the right side of the firebox 16 Connect the wire harness from the fan control to th...

Страница 38: ...SPEED CONTROL FAN SWITCH GROUND BLACK FAN WHITE BLACK SWITCH BRACKET FBBX Wiring Diagram FBBX BLOWER KIT EXTENSION INSTALLATION INSTRUCTIONS FBB4 OPTIONAL VARIABLE SPEED BLOWER 1 18858 Blower Base 2 R7649 Fan Control 3 R4192 Speed Control Knob 4 R4186 Speed Control 5 R7731 Blower 6 R7831 Blower Wire Harness 7 R7912 Fan Switch Wire Harness 8 R3529 Cordset ...

Страница 39: ... one side panel into firebox 5 Align clearance hole on brick panel bracket with screw hole in the left or right interior top of firebox Use two 10 x 1 2 screws to attach brick panel bracket to interior top of firebox 6 Repeat steps 4 and 5 to install second side panel 7 Replace rear log and branch log onto burner assembly 8 Replace screen onto fireplace 9 Installation of optional brick liner is co...

Страница 40: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Страница 41: ...e of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready ac...

Страница 42: ...30816 7 0814 Page 42 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Страница 43: ...30816 7 0814 Page 43 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Страница 44: ...rt Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: