30816-7-0814
Page 25
The VFD26F(M,P)(3,7) gas control maximum and minimum
inputs are listed below.
OFF is the OFF position.
PILOT is the PILOT position.
VFD26F(M,P)(3,7)
Max.
20,000 BTU/HR
Min.
14,000 BTU/HR
VFD26FP3L10 and VFD26FP(30,70)L10
Max. 10,000
Min. N/A
VFD26F(M,P)2 Main Burner Operation
The gas control modulates from a minimum input of 14,000 BTU/
HR ("LO" (1) setting) to a maximum input of 20,000 BTU/HR ("HI"
(5) setting).
Cleaning and Maintenance / Main Burner
WARNING
Turn off heater and let cool before cleaning.
CAUTION
You must keep control areas, burner and circulating air
passageways of heater clean. Inspect these areas of heater
before each use. Have heater inspected yearly by a qualified
service person. Heater may need more frequent cleaning due to
excessive lint from carpeting, bedding materials, etc.
Logs
Be careful cleaning and handling logs so as not to damage them.
If logs break or fall apart in handling, spray the broken pieces and
fibers with water, sweep up and discard.
MAIN BURNER AND THERMOSTAT OPERATION