SPCL36104-S Suction System
10.6
(N/A)
10.7
(N/A)
10.8
OSCILLATOR WILL NOT RUN
1.
Oscillator speed potentiometer set too slow.
2.
Door open or limit switch not made.
3.
Timer or Counter set to zero.
4.
Oscillator movement restricted.
5.
Internal adjustments on DC Motor Control Board (MIN, MAX, IR, CL, ACCEL,
DECEL). See Manufacturer’s literature.
6.
Blown control fuse.
7.
DC Motor Control Board failure.
8.
Check for the red brake light on the DC Motor Control Board. If it is illuminated,
there is no run signal. See Electrical Drawings and Manufacturer’s literature.
10.9
BLAST CABINET CONE FULL OF MEDIA - MUST BE REMOVED FROM CABINET
1.
Hole in recovery duct, dust hose, Reclaimer door open, Storage Hopper door open or
Dust Collector door open.
2.
Dust filters clogged or filter cleaning system not functional.
3.
Too much media flow.
4.
Media too large for conveying system.
5.
Media level in Storage Hopper Low.
6.
Debris blocking opening(s) to pickup tube.