Page 4
SPCL36104-S Suction System
2.0
INSTALLATION INSTRUCTIONS
Reference drawings are listed in Section 12.0.
2.1
Remove the system components from the skids and check for any damage which may have
occurred during shipment. IF DAMAGE IS FOUND, IT IS THE RESPONSIBILITY OF
THE CUSTOMER TO FILE AN INSURANCE CLAIM WITH THE SHIPPING
COMPANY. The system will be arranged as shown on the System Assembly Drawing.
Refer to the drawings listed in Section 12.0.
2.2
DUST COLLECTOR AND BLOWER ASSEMBLY
2.2.1 A Cartridge Dust Collector will require a Storage Hopper, legs, and in most cases, a
Blower Assembly. Instructions may be found packed with the hardware and drum
cover.
2.3
Position the Dust Collector. It may be placed anywhere within the reach of the connecting
dust hose. Keep in mind that dust must be removed from the Dust Collector. Filter access
doors of the Dust Collector must be positioned to allow maintenance, filter replacement and
access to the Reverse Pulse components.
2.4
The Reclaimer may have been removed from the Storage Hopper for shipment. Install it on
the Storage Hopper as shown on the Assembly Drawing. Be sure that the gasket between the
Reclaimer and hopper makes an airtight seal. This seal is critical for proper operation.
2.5
Position the Blast Cabinet and make sure it is level. Clear space must be available on both
sides of the Blast Cabinet for doors and access to the Main Electrical Enclosure, and at the
back of the Cabinet for maintenance and adjustments.
2.6
Assemble the dust hose from the Reclaimer outlet to the Dust Collector inlet. Secure the dust
hose at each end with the worm gear clamps provided. Connections must be airtight.
2.7
Assemble the heavy-duty conveying hose from the Blast Cabinet cone pickup tube to the
Reclaimer inlet.
2.7.1
Heavy-duty conveying hose is assembled to the Blast Cabinet cone pickup tube and
Reclaimer inlet. Secure the hose with the clamps provided. Connections must be
airtight.
2.7.2 (Optional) Urethane Duct is connected to the Blast Cabinet cone pickup tube and
Reclaimer adapters. Steel couplings are provided for connecting the urethane joints.
Sheet metal screws are provided for each adapter and coupling. All adapters and
couplings must be caulked (with RTV silicone) to insure an airtight seal.
2.7.2
(Optional) The Makeup Hopper is installed connecting the two (2) inch discharge or
six (6) inch steel tube to the conveying duct. The connection must be airtight. Apply
RTV silicone caulk around the hole in the Urethane Duct and two (2) inch discharge