Page 17
SPCL36104-S Suction System
6.11
Inspect all Oscillator limit switch arms for free movement and all split collar limit switch
trippers for tightness and proper orientation. Repair and/or adjust before operating the
system.
6.12
Replace all cracked or frosted windows, worn window curtains, and damaged door gaskets.
6.13
Turn the “BLAST” selector switch to “OFF”. Press the “SYSTEM ON” pushbutton.
6.14
Observe the operation of the rotating mandrel. Check that hoses do not rub on the interior of
the Blast Cabinet.
6.15
Turn the “BLAST” selector switch to “ON”. Observe blast from each nozzle. Pay special
attention to media flow, direction, and consistency of flow. Correct any problem before
operating the system. Refer to Section 9.0.
6.16
Press the red “SYSTEM OFF” pushbutton to shut the system down. On Bag Type Collectors,
listen for the Dust Collector Automatic Bag Shake to operate. If the Bag Shake does not
function, repair it before operating the system. Cartridge Dust Collectors Reverse Pulse clean
only when the system is “ON”.
6.17
PERIODIC CHECKS - (N/A)
6.18
MANDREL REPLACEMENT
If the Mandrel needs replacement due to different part diameters, locate the coupling that
secures the mandrel to the main drive shaft. Before loosening this coupling properly support
the mandrel through out its length then diassemble it. When installing a new mandrel be sure
to add the rubber washer that is located in between the end of the drive shaft and the matching
end of the mandrel. This washer creates the necessary seal required when appling air for the
I.D. blowoff.