29516-2-0912
Page 20
Figures 27 and 29 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner
flame meet. Figures 28 and 30 show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Correct Pilot Flame Pattern for MILLIVOLT
Figure 27
THERMOPILE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
Incorrect Pilot Flame Pattern for MILLIVOLT
Figure 28
If pilot flame pattern is incorrect, as shown in Figure 28
• See Millivolt Troubleshooting, page 27.
pILOT FLAME CHARACTERISTICS
PILOT
SENSOR
IGNITOR
Correct Pilot Flame Pattern for IP
Figure 29
PILOT
SENSOR
IGNITOR
Incorrect Pilot Flame Pattern for IP
Figure 30
If pilot flame pattern is incorrect, as shown in Figure 30.
• See IP Troubleshooting, pages 36 - 38.