
29516-2-0912
Page 8
FIREpLACE DIMENSIONS
A
B
C
D
E
F
G
H
I
J
K
Figure 1
When planning a fireplace insert installation, it’s necessary to
determine:
•
Gas supply piping.
•
Electrical connections - for optional light kit
•
Electrical supply requirements for optional light.
(120V, 60Hz, 1 Amp)
•
Proper opening size of fireplace required for installation of
the fireplace insert.
vF FIREpLACE DIMENSIONS (in inches)
MODEL
A
B
C
D
E
F
G
H
I
J
K
VFLL38FP
43-1/4 35-1/4 11-31/32
38-1/4
41-5/8
11-15/32
1/2
10-15/16
15/16
21-1/8
13
Figure 2
Figure 3
NOTE: you must use the standoffs that are supplied with the
fireplace. The standoffs are shipped in a flat-state on top of
the fireplace.
1. Locate the two steel standoffs on top of the fireplace.
2. Remove the two screws that secure the standoffs in place;
save the screws.
3. The standoffs have a perforation located in the middle. Bend
them at the perforation.
4. Bend the short tabs on each end in opposite directions. Se-
cure the standoffs to the fireplace top with three screws each
from the hardware bag. There are pilot holes located in the
top of the fireplace for each stand-off. See Figure 2
5. Use pliers to bend the side standoffs 90 degrees. See Figure
3.
6. Locate framing bracket package. Install six framing brackets
with two 10 x 1/2 screws (each). See Figures 2 and 3.
Содержание VFLL38FP30LN-1
Страница 43: ...29516 2 0912 Page 43 EXPLODED VIEW...
Страница 45: ...29516 2 0912 Page 45 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 46: ...29516 2 0912 Page 46 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...
Страница 47: ...29516 2 0912 Page 47 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...