In planning the installation for the fireplace, determine where the 

unit is to be installed and whether optional accessories are desired. 

Gas supply piping should also be planned at this time.

The fireplace can be mounted on any of these surfaces:

1.  A flat hard combustible or non-combustible surface.

2.  A raised platform of combustible or non-combustible material.

3.  Four (4) corners of the fireplace so contact is made on all four 

perimeter edges on the bottom of the unit. 

If the fireplace is installed directly on carpeting, tile or other 

combustible material other than wood flooring, it should be installed 

on a metal or wood panel extending the full width and depth of the 

unit.

This unit is designed to be installed in a zero-clearance enclosure. 

This means the combustible material can come in contact with the 

firebox.

Built-In Fireplace Installation

Built-in  installation  of  this  fireplace  involves  installing  the 

 

fireplace into a framed-in enclosure. This makes the front of the 

fireplace flush with a wall. 

Frame in rough opening. Use dimensions show in Figure 4 for a 

conventional rough opening. Use dimensions shown in Figure 5 

for corner rough opening. Use Figure 6 for an elevated installation. 

Be sure to provide support to the bottom of the fireplace. Be sure 

to provide gas line for fireplace and electrical power for optional 

light assembly.

1.  Gas line connections must be made at this time. When  

facing the appliance, the gas supply will enter on the left-hand 

side. See "Gas Supply" page 12 to 13.

2.  Insert fireplace into enclosure. 

3.  Level firebox. 

4.  Secure six framing brackets with drywall screws to the framed 

opening  above  the  fireplace  as  shown  in  figures  4  and  6. 

These brackets should be installed flush with the framing, and 

are used to support the ends of the non-combustible board to 

the framing brackets. Note: The framing brackets and drywall 

screws are located in the instruction envelope packet.

5.  Finished wall surface will be flush to the leading edge of fire

-

place top and sides.

6.  If used, the surround panel assembly is installed after the fire

-

place has been installed with all the gas and electrical con-

nections completed. Refer to instructions included with the 

surround panel kit.

7.  Installation of built-in fireplace is completed.

BUILT-IN FIREpLACE INSTALLATION

Rough Opening for Installing in Wall

Rough Opening for Installing in Corner

D

34 1/2”

876.3mm

B

69” (1752.6mm)

Rough Opening for Elevated Installation

A

B

C

D

VFLL38FP

13 3/4"

349.3mm

43 1/2"

1104.9mm

35 1/4"

895.4mm

48 13/16"

1239.8mm

Figure 4

Figure 5

Figure 6

Содержание VFLL38FP30LN-1

Страница 1: ...life Installer Leave this manual with the appliance Consumer Retain this manual for future reference EMPIRE EMPIRE Comfort Systems This appliance may be installed in an aftermarket permanently located...

Страница 2: ...15 DECORATIVE ACCESSORY INSTALLATION 16 17 MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS 18 IP LIGHTING INSTRUCTIONS 19 PILOT FLAME CHARACTERISTICS 20 21 OPERATION INSTRUCTIONS FLAME APPEARANCE 22 CLE...

Страница 3: ...to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazard of high surface temperature and should st...

Страница 4: ...rform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls...

Страница 5: ...nt free appliance If the air blows directly into the flame causing it to disrupt the flame it should be turned off or redirected Ceiling fans could be reversed to possibly eliminate flame impingement...

Страница 6: ...rifice size Well Head Gas Installations Some natural gas utilities use well head gas This may affect the Btuoutputoftheunit Contactthegascompanyfortheheatingvalue Contact the manufacturer or your gas...

Страница 7: ...r Shutter Opening FULL OPEN 1 8 SPECIFICATIONS OPTIONAL ACCESSORIES Part Number Description DF38CBLHP Decorative Front Cascade Black and Pewter DF38WHP Decorative Front Pewter DF38WBL Decorative Front...

Страница 8: ...e standoffs that are supplied with the fireplace The standoffs are shipped in a flat state on top of the fireplace 1 Locate the two steel standoffs on top of the fireplace 2 Remove the two screws that...

Страница 9: ...Figure 6 for an elevated installation Be sure to provide support to the bottom of the fireplace Be sure to provide gas line for fireplace and electrical power for optional light assembly 1 Gas line c...

Страница 10: ...or less with openings gasketed or sealed and b Weather stripping has been added on openable windows and doors and c Caulking or sealants are applied to areas such as joints around window and door fra...

Страница 11: ...BTUH of the total input rating of the gas equipment in the confined space Figure 7 WARNING Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough fre...

Страница 12: ...hutoffvalvemustbedisconnected fromsupplypipingsystemduringanypressuretestingofthatsystem at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supply piping system...

Страница 13: ...mly to re seal Do not over torque Check for gas leaks Checking Manifold Pressure MILLIVOLT VALVES Natural gas will have a manifold pressure of approximately 3 5 w c for maximum input or 1 6 w c for mi...

Страница 14: ...6 MINIMUM CLEARANCE TO PERPENDICULAR COMBUSTIBLE SIDE WALL 36 MINIMUM CLEARANCE TO CEILING Figure 12 CLEARANCES FINISHED WALL FLAT MANTEL SHELF 2 22 18 4 6 8 10 12 20 24 26 28 NON COMBUSTIBLE MATERIA...

Страница 15: ...The flow of heat can ignite combustibles Do not attach combustible material to the mantel of your fireplace This is a fire hazard Figure 14 No greeting cards stockings or ornamentation of any type sh...

Страница 16: ...ORATIVE GLASS ACCESSORY PLACEMENT The Decorative Glass options are available in various colors and package sizes Choose the size appropriate for your fireplaces See list on page 7 CAUTION Use of glove...

Страница 17: ...pply the remaining decorative glass to the front sloped surface of the Top Cover Start by placing the glass along the front edge of the top cover then gradually place the glass up the sloped top until...

Страница 18: ...knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF un less knob is pushed in slightly Do not force 6 Wait ten 10 minutes to clear out any gas Then smell for gas incl...

Страница 19: ...remote instructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property dam...

Страница 20: ...le to cool When the thermocouple cools the heater will shut down THERMOPILE PILOT THERMOCOUPLE LPG THERMOCOUPLE NATURAL Correct Pilot Flame Pattern for MILLIVOLT Figure 27 THERMOPILE PILOT THERMOCOUPL...

Страница 21: ...the pilot tubing When this procedure is required grasp nut A with an open end wrench 2 Blow air pressure through the holes indicated by the arrows This will blow out foreign materials such as dust li...

Страница 22: ...ng by your dealer or qualified service technician is recommended to prevent malfunction and or sooting TURN OFF HEATER AND ALLOW TO COOL BEFORE CLEANING Remove any optional decorative covers or decora...

Страница 23: ...ng the appliance the remote receiver must be placed to the left of the gas valve Refer to remote control installation and operating instructions for more details on remote control Figure 33 H N REMOTE...

Страница 24: ...ransmitter This is part of the system s design If the signal light does not illuminate check the position of the transmitter s battery REMOTE RECEIVER Figure 35 The remote receiver operates on 4 AA si...

Страница 25: ...s not included be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the remote receiver For the best results use 18 g...

Страница 26: ...iver signals between the remote receiver and the gas valve Recommended length is no longer than 20 feet The transmitter should operate with as little as 5 0 volts battery power TROUBLE SHOOTING If you...

Страница 27: ...l knob not pressed in while in PILOT position Press in control knob while in PILOT position d Airingaslineswheninstalled Continueholdingdowncontrol knob Repeat igniting operation until air is removed...

Страница 28: ...TENANCE OF THE RECEIVER PLACE THE RECEIVER S 3 POSITION SLIDER SWITCH IN THE OFF POSITION DURING INSTALLATION OR MAINTENANCE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING...

Страница 29: ...ild safety lock out Room Temperature Set Point Temperature Level State Flame ON Thermostat OFF ON SMART Transmission Figure 39 Transmitter LCD display RECEIVER The Proflame Receiver Figure 40a and 40b...

Страница 30: ...articular code of that Transmitter The system is now initialized Temperature indication Display With the system in the OFF position press the Thermostat Key and the Mode Key at the same time Look at t...

Страница 31: ...he Down Arrow Key once will reduce the flame height by one step un til the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed wh...

Страница 32: ...re is displayed on the LCD screen of the Transmitter SET TEMPERATURE ROOM TEMPERATURE Figure 48a Figure 48b Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame heigh...

Страница 33: ...n will disappear Figure 52 Receiver The life span of the Receiver batteries depends on various factors quality of the batteries used the number of ignitions of the appli ance the number of changes to...

Страница 34: ...llowing gas to flow to the burner 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for In termittent Pilot controls found in this manual and on labels found in the control compartment located in the lowe...

Страница 35: ...ate the appliance with panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person WARNING Improper installation adjustment alteration service...

Страница 36: ...e 19 and Wiring Diagram on page 35 Troubleshooting Before proceeding with the procedures in the following trouble shooting table verify that the power supply AC DC adapter is present and that the batt...

Страница 37: ...4 Replace the DFC board 1 Verify the electrical connections integrity and make sure they are in accordance with the relevant system wiring diagram If necessary replace the wire harness 2 If pilot flow...

Страница 38: ...oltage at ignition between the EV1 terminal and the ground connection on the valve body 5 1 If the voltage is greater than 0 then Replace Valve 5 2 Or Replace DFC 6 Check the pressure at the outlet pr...

Страница 39: ...ing detail refer to Figure 54 INSTALLATION 120 Volt electrical requirements will depend on which model fireplace is installed For VFLL38FP30L series millivolt operated system Wiring is only needed if...

Страница 40: ...e of the receptacle and the white wire to the opposite side Secure the incoming ground wire under the green ground screw provided on the receptacle Figure 57 Figure 58 5 If only installing the LK5 Acc...

Страница 41: ...st Street Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS...

Страница 42: ...15 29464 TUBING ASSEMBLY REGULATOR TO PILOT 17 29463 TUBING ASSEMBLY VALVE TO REGULATOR 18 29466 BURNER BOX FRONT 19 R9761 PIEZO IGNITOR 20 26304 IGNITOR BRACKET 21 29462 CENTER SUPPORT 24 R6062 TRANS...

Страница 43: ...29516 2 0912 Page 43 EXPLODED VIEW...

Страница 44: ...te control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The a...

Страница 45: ...29516 2 0912 Page 45 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 46: ...29516 2 0912 Page 46 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 47: ...29516 2 0912 Page 47 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 48: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Отзывы: