31449-14-0116
Page 59
The OWNER should carefully read and follow these operating
instructions at all times. Lower the door assembly to view the gas
controls for the fireplace.
Initial Lighting
Upon completing the gas line or turning the gas valve on after it has
been in the “OFF” position, a small amount of air will be in the lines.
When first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is complete,
the fireplace will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging
if the gas valve is not turned to “OFF.”
Pilot Flame
The thermopile/thermocouple (standing pilot) tips should be covered
with flame.
Figure 70
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning
pilot. The pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermopile produces millivolts (electrical
current) which energizes the magnet in the gas valve. After 30
seconds to 1 minute time period you can release the gas control
knob and the pilot will stay ON. Allow your pilot flame to operate
an additional one to two minutes before you turn the gas control
knob from the PILOT position to the ON position. This time period
allows the millivolts (electrical current) to build-up to a sufficient
level allowing the gas control to operate properly.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for standing
pilot controls found in this manual and on labels found in control
compartment behind the door assembly.
CAUTION
:
During the initial purging and subsequent
lightings, never allow the gas valve control knob to remain
depressed in the “pilot” position without pushing the piezo
ignitor button at least once every second.
2. During the operating season, leave the control valve knob in the
“ON” position. This will allow the pilot flame to remain lit. Turn
the burner flame on or off with the fireplace Remote/OFF/ON
switch, wall switch or remote controls.
NOTICE
:
The gas control valve allows you to increase or decrease
the height of the main burner flame. The control valve has a pressure
regulator with a knob as shown in Figure 69. Rotate the knob
clockwise to “HI” to increase the flame height and counterclockwise
to “LO” to decrease the flame height.
3. When the operating season is over, turn the Remote/OFF/ON
switch to “OFF” and the control valve to “OFF”. The system,
including the pilot light, will be shut down.
HI/LO REGULATOR
CONTROL KNOB
Figure 69
MILLIVOLT SYSTEM OPERATING INSTRUCTIONS
Содержание MILLIVOLT STANDING PILOT DVX36FP31LN-4
Страница 51: ...31449 14 0116 Page 51 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Страница 53: ...31449 14 0116 Page 53 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Страница 56: ...31449 14 0116 Page 56 LOG PLACEMENT 17 The log assembly is now complete...
Страница 83: ...31449 14 0116 Page 83 PARTS VIEW Note Refer to page 45 when ordering logs...