DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)
7. Remove outside mounting plate with tube attached from wall.
Mark and cut the extra length of the 6 5/8” (168mm) diameter
tube from the opposite end. Do not crimp or enlarge tube.
8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid
venting system or directly to fireplace. Ensure the 4” (102mm)
diameter flue outlet tube is placed as far as possible onto the
rigid venting system. Mark the 4” (102mm) diameter flue outlet
tube 2 1/2” (64mm) beyond the vinyl siding kit or wall. S
ee
Figure 56.
Remove the 4” (102mm) diameter flue outlet tube
from rigid venting system. When installing directly to fireplace,
tape gasket needs to be used.
Figure 56
9. Mark or wrap tape completely around the tubes at the marked
points to help in making a true cut. Do not crimp or enlarge
tubes.
10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/
mounting plate onto end of rigid venting system to correct posi-
tion. Fasten the outside mounting plate to the vinyl siding kit or
wall with 10 x 1 1/2” screws. (Ensure upward slope).
11. From inside: Attach the inlet tube to the collar on the back of the
fireplace (or the rigid venting system) using three self tapping
screws.
Figure 57
12. Seal the 4” (102mm) diameter flue outlet tube. Follow instruc
-
tions and diagram.
See
Figure 58
.
13. Fasten 4” (102mm) diameter flue outlet tube in place. Do not
“twist” the flue outlet tube into the fireplace collar (or rigid vent
-
ing system). Hold the tube by the seam and push in using a
perpendicular “rocking” motion. This ensures the seam on the
tube stay intact.
14. Fasten vent cap end using three 10 x 1/2” screws to mounting
plate.
Sealing 4” (102mm) Diameter Flue Outlet Tube
1”
VENT CAP END
APPLY SEALANT
ON THE INSIDE
DO NOT PLACE
OVERLAPPED
SECTION OVER
THE SEAM IN THE TUBE
Figure 58
Note:
Tape gasket to be applied prior to installing to fireplace flue
outlet tube only. Tape gasket should not be used when mating the
flue outlet tube to a rigid venting system.
Содержание MILLIVOLT STANDING PILOT DVX36FP31LN-4
Страница 51: ...31449 14 0116 Page 51 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Страница 53: ...31449 14 0116 Page 53 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Страница 56: ...31449 14 0116 Page 56 LOG PLACEMENT 17 The log assembly is now complete...
Страница 83: ...31449 14 0116 Page 83 PARTS VIEW Note Refer to page 45 when ordering logs...