DVVK-4FV DIRECT VENT TERMINATION KIT
INSTALLATION INSTRUCTIONS
This termination kit can only be used with Empire Comfort Sys-
tems direct vent fireplaces listed for use with DVVK-4FV Verti
-
cal Flex Vent Kit. Please review the instructions packaged with
your fireplace and verify the fireplace model number. Check
that this flex vent system is listed for use with your fireplace
model prior to starting the installation.
This vent kit may be installed as an OEM installation in a
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer’s instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240 MH.
CAUTION
All Fireplaces listed for use with the DVVK-4FV will operate
safely when installed in accordance with this instruction manu-
al. Read all instructions before starting installation, then follow
these instructions carefully to maximize fireplace performance
and safety. Report damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV vent kit
with other gas appliances is not allowed. Do not connect this ap-
pliance to a chimney flue servicing a separate solid fuel-burning
appliance.
WARNING
Failure to follow these instructions may create a possible
fire hazard and will void the warranty.
WARNING
Always maintain minimum clearances around vent systems.
The minimum clearance to combustibles for horizontal runs of
vent pipe is 3 inches from the top, and 1 inch from the sides
and bottom of the vent system. Do not pack the open air spaces
around the fireplace or flue with insulation or other materials.
Any horizontal run must have a 1/4” rise for every one foot of
run towards the vent termination. The vent above the roof must
terminate vertically.
WARNING
Contact your Local Building and Fire Officials about restric-
tions and installation inspections in your area.
IMPORTANT SAFETY INFORMATION
• The vertical termination cap MUST be vented directly to the
outside. The termination kit MUST NEVER be connected to a
chimney flue(s) servicing a separate solid-fuel burning appli
-
ance or any other appliances.
•
Termination cap MUST NOT be mounted horizontally.
•
The flexible vent pipe cannot be intermingled with any of the
rigid vent pipe section(s). DO NOT connect two sections of
flexible vent pipe together to achieve a longer length without
the use of approved connectors.
• The installation must conform with local codes or in the ab-
sence of local codes, with the National Fuel Gas Code, ANSI
Z223.1 (in the United States) or with the current installation
code CAN/CGA B149 (in Canada).
•
Only Direct Vent fireplaces approved for use with Empire
Comfort Systems, Inc. DVVK-4FV termination kit shall be
used. See PARTS LIST/ILLUSTRATIONS section for vent
component identification.
• Horizontal vent runs must be supported every 2 feet using
wall straps. Vertical runs must be supported every 3 feet using
wall straps. Slip wall straps loosely on to pipe. Attach installer
provided straps to framing members using nails or screws.
•
The fireplace and venting system should be inspected before
initial use and at least annually by a qualified field service per
-
son. Inspect the external vent cap on a regular basis to make
sure that no debris is interfering with the airflow. Inspect entire
venting system to ensure proper function.
•
Please refer to the fireplace instructions for information on
Termination Cap clearances.
Содержание MILLIVOLT STANDING PILOT DVX36FP31LN-4
Страница 51: ...31449 14 0116 Page 51 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Страница 53: ...31449 14 0116 Page 53 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Страница 56: ...31449 14 0116 Page 56 LOG PLACEMENT 17 The log assembly is now complete...
Страница 83: ...31449 14 0116 Page 83 PARTS VIEW Note Refer to page 45 when ordering logs...