31449-14-0116
Page 14
DVX36 DVX42
"A"
40 7/8" 40 7/8"
"B"
39 3/8" 43 3/8"
"C" 19 7/8" 19 7/8"
Attention:
Add 3-3/4" to “A” dimensions when using a flush mantel
base.
Figure 14
WARNING
If a base or mantel is not used and the appliance is installed directly
on carpeting, tile or other combustible material other than wood
flooring, it shall be installed on a metal or wood panel extending
the full width and depth of the appliance. The vertical dimension
in
Figure 14
must be adjusted when a metal or wood panel is
placed beneath the appliance.
Finishing - See Figures 15 and 16
Finish the walls with the material of your choice.
Figure 5
on page 10
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the fireplace.
Only non-combustible materials may be used to cover the black
fireplace front.
WARNING
When finishing the fireplace never obstruct or modify the air
inlet/outlet louvers in any manner. Provide adequate clearances
around air openings into the combustion chamber.
CAUTION
If the joints between the finished wall and the fireplace surround
(top and sides) are sealed, a 300°F minimum sealant material
must be used. These joints are not required to be sealed. Only
non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the fireplace surround.
Flush Mount Mantel Installation
The fireplace must extend 3/4" beyond finished wall surface when
using a flush mount mantel. Refer to
Figure 13
to locate nailing
flanges on fireplace sides. Mark and drill two 1/8" holes into fireplace
side to mount each nailing flange. Use eight 1/2" hex-head screws
supplied in hardware package to attach nailing flanges to fireplace
sides.
NAIL OR OTHER
SUITABLE FASTENER
Figure 13
Attention:
When fireplace is installed in optional full cabinet mantel
or corner mantel the four nailing flanges shown in
Figure 13
will
not be installed on the side of outer casing. The fireplace will be
attached to the full cabinet mantel or corner mantel with the two
nailing flanges located on the top of the outer casing assembly.
Framing
Fireplace framing can be built before or after the fireplace is set in
place. Framing should be positioned to accommodate wall covering
and fireplace facing material. The fireplace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the fireplace standoffs. Refer to
Figure 14
for minimum
framing dimensions.
CAUTION
MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING
METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
Framing dimension "A" includes a six inch clearance for
standoffs on firebox. After installing firebox into framing,
the finished wall surface must cover the six inch opening
above the firebox.
INSTALLATION (continued)
Содержание MILLIVOLT STANDING PILOT DVX36FP31LN-4
Страница 51: ...31449 14 0116 Page 51 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Страница 53: ...31449 14 0116 Page 53 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Страница 56: ...31449 14 0116 Page 56 LOG PLACEMENT 17 The log assembly is now complete...
Страница 83: ...31449 14 0116 Page 83 PARTS VIEW Note Refer to page 45 when ordering logs...