SEE GRAPH FOR PERMISSIBLE “H” AND “V” DIMENSIONS
FIRESTOP AT
CEILING LEVEL
Figure 22
Examples of possible venting systems using two 90° elbows.
V is listed as minimum vertical dimensions and H1 + H2 is listed
as total of maximum horizontal dimensions. The maximum vertical
and horizontal distances for two 90° elbows as shown in
Figure
23
is 22 feet.
Attention: Refer to
Figure 20
for additional venting requirements.
Figure 23
Below Grade Installation
When it is not possible to meet the required vent terminal clearances
of 12" (305mm) above grade level, a snorkel kit is recommended.
It allows installation depth down to 7" (178mm) below grade level.
The 7" (178mm) is measured from the center of the horizontal vent
pipe as it penetrates through the wall.
Ensure the sidewall venting clearances are observed. If venting
system is installed below ground, we recommend a window
well with adequate and proper drainage to be installed around
the termination area.
TYPICAL BASEMENT INSTALLATION
Figure 21
Examples of possible venting systems using one 90° elbow. Eight
feet is listed as minimum vertical vent run with 20 feet of maximum
horizontal vent run. Vertical dimensions are based on centerline to
centerline of pipe. Horizontal dimensions are based on centerline
of pipe to end of termination.
VENTING FIREPLACE - TOP (continued)
Содержание MILLIVOLT STANDING PILOT DVX36FP31LN-4
Страница 51: ...31449 14 0116 Page 51 LOG PLACEMENT 12 Place Log I on the two left pins of Log B as shown below...
Страница 53: ...31449 14 0116 Page 53 LOG PLACEMENT 14 Place Log K on far right pin of Log B as shown below...
Страница 56: ...31449 14 0116 Page 56 LOG PLACEMENT 17 The log assembly is now complete...
Страница 83: ...31449 14 0116 Page 83 PARTS VIEW Note Refer to page 45 when ordering logs...